![background image](http://html1.mh-extra.com/html/magnetek/hpv-600/hpv-600_technical-manual_3605624059.webp)
Open-loop Motor A5
59
Adjust A0 menu
Motor A5 submenu
A5
parameter
description
default
units
min
max
hidden
item
run
lock
out
MOTOR ID
Motor Identification
none
N
Y
RATED MTR POWER
Rated motor output
power
Per ID
HP or
KW
1.0
500.0 N
Y
RATED MTR VOLTS
Rated motor terminal
RMS voltage
Per ID
Volts
190.0
575.0
N
Y
RATED EXCIT FREQ
Rated excitation
frequency
Per ID
Hz
5.0
400.0
N
Y
MOTOR MID VOLTS
Voltage at middle
frequency. Limited by
the motor’s rated
voltage.
Per ID
Volts
0.1
575.0
N
Y
MOTOR MID FREQ
Middle frequency
point used to define
the V/Hz profile.
Per ID
Hz
0.1
400.0
N
Y
MOTOR MIN VOLTS
Voltage at minimum
frequency.
Per ID
Volts
0.1
100.0
N
Y
MOTOR MIN FREQ
Minimum frequency
point used to define
the V/Hz profile.
Per ID
Hz
0.1
10.0
N
Y
RATED MOTOR CURR
Rated motor current
Per ID
Amps
1.00
800.00
N
Y
MOTOR POLES
Motor poles
Per ID
none
2
32
N
N
RATED MTR SPEED
Rated motor speed at
full load
Per ID
RPM
50.0
3000.0
N
N
% NO LOAD CURR
Percent no load
current
Per ID
% rated
motor
current
10.0 80.0
N
N
STATOR LEAKAGE X
Stator leakage
reactance
Per ID
% base
Z
0.0 20.0
Y
N
ROTOR LEAKAGE X
Rotor leakage
reactance
Per ID
% base
Z
0.0 20.0
Y
N
STATOR RESIST
Stator resistance
Per ID
% base
Z
0.0 20.0
Y
N
MOTOR IRON LOSS
Iron loss at rated
frequency
Per ID
% rated
power
0.0 15.0
Y
N
MOTOR MECH LOSS
Mechanical loss at
rated frequency
Per ID
% rated
power
0.0 15.0
Y
N
OVLD START LEVEL
Maximum continuous
motor current
Per ID
% rated
current
100 150
Y
Y
OVLD TIME OUT
Time that defines
motor overload curve
Per ID
seconds
5.0
120.0
Y
Y
Содержание HPV 600
Страница 1: ...HPV 600 AC Elevator Drive Technical Manual...
Страница 162: ......
Страница 163: ......