![background image](http://html1.mh-extra.com/html/magnetek/hpv-600/hpv-600_technical-manual_3605624103.webp)
Closed-loop User Switches C1
103
Configure C0 menu
User Switches C1 submenu
C1
parameter
description
default
choices
hidden
item
run
lock
out
SPD COMMAND SRC
Speed Command
Source
MULTI-STEP analog
input
multi-step
serial
ser mult step
Y Y
RUN COMMAND SRC
Run Command
Source
EXTERNAL TB
external tb
serial
extrn
Y Y
HI/LO GAIN SRC
High / low gain
change switch source
INTERNAL external
tb
serial
internal
Y Y
SPEED REG TYPE
Chooses speed
regulator: Ereg or PI
regulator
ELEV SPD REG
elev spd reg
pi speed reg
external reg
Y Y
MOTOR ROTATION
Allows user to
reverse direction of
motor rotation.
FORWARD forward
reverse
Y Y
SPD REF RELEASE
Determines when
speed reference
release is asserted
(for use when the
drive controls the
mechanical brake)
REG RELEASE
reg release
brake picked
Y Y
CONT CONFIRM SRC
Determines if an
external logic input is
used for contactor
confirm.
NONE none
external tb
Y Y
PreTorque SOURCE
Determines if a pre
torque command is
used and if used, it
determines the
source of the pre
torque command.
NONE none
analog input
serial
Y Y
PreTorque LATCH
Chooses if analog
pre-torque command
is latched
EXTERNAL TB
external tb
serial
Y Y
PTorq LATCH CLCK
Determines source of
pre torque latch
control (if used)
NONE none
external tb1
Y Y
FAULT RESET SRC
Fault reset source
EXTERNAL TB
external tb
serial
automatic
Y Y
OVERSPD TEST SRC
Determines external
logic source to initiate
overspeed test
EXTERNAL TB
external tb
serial
Y Y
BRAKE PICK SRC
Determines the
source of the brake
pick command
(if drive controls
mechanical brake)
INTERNAL internal
serial
Y Y
BRAKE PICK CNFM
Determines if a logic
input is used for
brake pick confirm
NONE none
external tb
Y Y
Содержание HPV 600
Страница 1: ...HPV 600 AC Elevator Drive Technical Manual...
Страница 162: ......
Страница 163: ......