Open-loop Power Data D2
79
Display D0 menu
Power Data D2 submenu
D2
parameter
description
units
hidden
item
MOTOR CURRENT
RMS motor current
Amps
N
% MOTOR CURRENT
Percent motor current
%rated current
N
MOTOR VOLTAGE
RMS motor terminal voltage
Volts
N
MOTOR FREQUENCY
Electrical frequency output
Hz
N
MOTOR TORQUE
Calculated motor torque output
% rated torque
N
POWER OUTPUT
Calculated drive power output
KW
N
DC BUS VOLTAGE
Measured DC bus voltage
Volts
N
SLIP FREQUENCY
Commanded slip frequency
Hz
Y
MOTOR OVERLOAD
Percent of motor overload trip level reached
%
Y
DRIVE OVERLOAD
Percent of drive overload trip level reached
%
Y
FLUX CURRENT
Measured flux producing current
%rated current
Y
TORQUE CURRENT
Measured torque producing current
%rated current
Y
FLUX VOLTAGE
Flux voltage reference
% rated volts
Y
TORQUE VOLTAGE
Torque voltage reference
% rated volts
Y
BASE IMPEDANCE
Drive calculated base impedance
Ohms
Y
EST STATOR RESIST
Approximate estimate of the motor’s stator resistance
(do not use for tuning drive)
% base
impedance
Y
Detailed description
MOTOR CURRENT
(RMS Motor Current Output)
Monitors the RMS motor output current.
% MOTOR CURRENT
(Percent Motor Current)
Monitors the motor current as a percent of rated
motor current.
MOTOR VOLTAGE
(Motor Voltage Output)
Monitors the RMS motor terminal line-line
voltage.
MOTOR FREQUENCY
(Motor Frequency Output)
Monitors the electrical frequency of the motor
output.
MOTOR TORQUE
(Motor Torque Output)
Calculated motor output torque in terms of
percent rated torque.
POWER OUTPUT
(Power Output)
Calculated drive power output.
DC BUS VOLTAGE
(DC Bus Voltage)
Measured voltage of the DC bus.
SLIP FREQUENCY
(Slip Frequency)
Displays the commanded slip frequency of the
motor.
MOTOR OVERLOAD
(Motor Overload)
Displays the percentage of motor overload trip
level reached. Once this value reaches 100%
the motor has exceeded its user defined
overload curve and a motor overload alarm is
declared by the drive. For more information on
the motor overload curve., see page 62.
DRIVE OVERLOAD
(Drive Overload)
Displays the percentage of drive overload trip
level reached. Once this value reaches 100%
the drive has exceeded its overload curve and a
drive overload fault is declared.