Open-loop User Switches C1
68
TORQUE CALC SEL
(Torque Calculation Select)
This parameter select between one of two
methods for calculating torque in the motor. The
result is used to produce the proper voltage
boost at low speed. This parameter is meant for
advanced operation, therefore, the parameter
will rarely need to be changed from the default
value.
DRV FAST DISABLE
(Drive Fast Disable Function)
This function determines how fast the drive
responses to the removal of DRIVE ENABLE
logic input. Note: The removal of the DRIVE
ENABLE logic input will turn-off the drive output
gates.
Disable
With the removal of the DRIVE ENABLE logic
input, the drive’s output gates will turn off within
4 msec.
Enable
With the removal of the DRIVE ENABLE logic
input, the drive’s output gates will turn off within
1.5-2.0 msec.