Closed-loop Drive A1
83
A1
parameter
description
default
units
min
max
hidden
item
run
lock
out
FLT RESETS / HOUR
Number of faults that
is allowed to be
automatically reset
per hour
3 faults
0
10 Y N
UP TO SPD. LEVEL
Threshold for up to
spd logic output
80.00 %
contract
speed
0.00 110.00 Y
N
MAINS DIP SPEED
Multiplier for contract
speed when in ‘low
voltage’ mode
25.00 %
0.00 99.99
Y
N
RUN DELAY TIMER
Allows the user to
delay the drive’s
recognition of the
RUN signal
0.00 seconds
0.00
0.99
Y
Y
AB ZERO SPD LEV
Sets the speed point
that will be
considered as zero
speed for the auto
brake function
0.00 %
0.00
2.00
Y
Y
AB OFF DELAY
Determines the time
after zero speed is
that the Auto Brake
logic output goes
false
0.00 seconds
0.00
9.99
Y
Y
CONTACTOR DO DLY
Allows the user to
delay the drive’s
dropout of the motor
contactor.
0.00 seconds
0.00
5.00
Y
Y
TRQ LIM MSG DLY
Determines the
amount of time the
drive is in torque limit
before the alarm
message is
displayed.
0.50 seconds
0.00
10.00 Y
Y
SER2 INSP SPD
Defines the serial
mode 2 inspection
speed
(only serial mode 2)
30.0
0.150
ft/min or
m/sec
0.0
0.000
100.0
0.500
Y Y
SER2 RS CRP SPD
Defines the creep
speed that will be
used in the “rescue
mode”
(only serial mode 2)
10.0
0.050
ft/min or
m/sec
0.0
0.000
300.0
1.500
Y Y
SER2 RS CPR TIME
Defines the maximum
time the drive will
continue to run at
rescue creep speed
(only serial mode 2)
180.0 seconds
0.0 200.0
Y
Y
SER2 FLT TOL
Defines the maximum
time that may elapse
between valid run
time messages
before a serial fault is
declared
(only serial mode 2)
0.04 seconds
0.00
2.00
Y
Y
ROLLBACK GAIN
Anti-rollback gain
1
none
1
99
Y
Y
NOTCH FILTER FRQ
Notch filter center
frequency
20 Hz 5 60
Y
Y