Open-loop Drive A1
44
Adjust A0 menu
Drive A1 submenu
A1
parameter
description
default
units
min
max
hidden
item
run
lock
out
CONTRACT CAR SPD
Elevator contract
speed
200.0
1.000
fpm
or m/s
0.0
0.00
3000.0
16.00
N Y
CONTRACT MTR SPD
Motor speed at
elevator contract
speed
1130.0 rpm
50.0 3000.0
N
Y
CONTACT FLT TIME
Time delay before
enabling drive outputs
and time before a
contactor fault is
declared (when drive
is controlling motor
contactor)
0.10 seconds
0.10
5.00
N
N
CONT DWELL TIME
Time delay when
disabling enabling
drive outputs to open
motor contactor and
delays contactor fault
(when drive is
controlling motor
contactor)
0.50 seconds
0.00
5.00
N
N
BRAKE PICK TIME
Time before a brake
pick fault is declared
(when drive is
controlling mechincal
brake)
1.00 seconds
0.00
5.00
N
N
BRAKE HOLD TIME
Time before a brake
hold fault is declared
(when drive is
controlling mechincal
brake)
0.20 seconds
0.00
5.00
N
N
BRAKE PICK DELAY
The time delay from a
drive run command
until the brake is
picked. (when drive is
controlling mechincal
brake)
0.50 seconds
0.00
5.00
N
Y
BRAKE DROP DELAY
If ramp to stop is
selected, this
parameter sets the
time delay to set the
brake after
decelerating to the
greater of DC Start
Freq or Motor Min
Freq. (when drive is
controlling mechincal
brake)
0.50 seconds
0.00
5.00
N
Y
DC START LEVEL
The level of DC
injection current at
start as a percent of
motor rated current.
50.0 %
rated
motor
current
0.0 150.0 N
Y