Open-loop Multistep Ref A3
56
Adjust A0 menu
Power Convert A4 submenu
A4
parameter
description
default
units
min
max
hidden
item
run
lock
out
Id REG DIFF GAIN
Flux current regulator
differential gain
0.50 none 0.10
2.00
Y
N
Id REG PROP GAIN
Flux current regulator
proportional gain
0.30 none 0.10
1.00
Y
N
Iq REG DIFF GAIN
Torque current
regulator differential
gain
1.00 none 0.10
2.00
Y
N
Iq REG PROP GAIN
Torque current
regulator proportional
gain
0.30 none 0.10
1.00
Y
N
Id DIST LOOP GN
Flux current distortion
loop gain
0.50 none 0.00
1.50
Y
N
Iq DIST LOOP GN
Torque current
distortion loop gain
0.30 none 0.00
1.50
Y
N
Id DIST LOOP Fc
Flux current distortion
loop corner frequency
5.0 Hz 0.1
30.0
Y N
Iq DIST LOOP Fc
Torque current
distortion loop corner
frequency
5.0 Hz 0.1
30.0
Y N
I REG CROSS FREQ
Current regulator
crossover frequency
100.0
% of DC
stop
freq.
0.0 300.0
Y
N
DIST LP OFF FREQ
Distortion loop rolloff
frequency
60.0 Hz
0.0 99.9
Y
N
ILIMT INTEG GAIN
Stall Prevention
(Current Limit)
integral gain
1.00
none
0.00
9.99
N
N
HUNT PREV GAIN
Torque slew rate
gain; increasing gain
slows drive torque
response
1.00 none 0.00
4.00
N
N
HUNT PREV TIME
Hunt prevention filter
time constant.
0.20 seconds
0.01
1.00
N
N
PWM FREQUENCY
Carrier frequency
10.0
kHz
2.5
16.0
N
N
SWITCHING DELAY
Transistor switching
delay
0.00
µ
sec
-5.00 5.00
Y
N
VC CORRECTION
Conduction voltage
correction
2.50 V
0.00
5.00
Y
N
UV ALARM LEVEL
Voltage level for
undervoltage alarm
90 %nomin
al dc
bus
80 99
N N
UV FAULT LEVEL
Voltage level for
undervoltage fault
80 %nomin
al dc
bus
50 99
N N
EXTERN REACTANCE
External choke
reactance
0.0 %
base
Z
0.0 10.0
N
Y
INPUT L-L VOLTS
Nominal line-line AC
input Voltage, RMS
460 or
230
Volts 110 480
N N