Fault F0
132
Fault F0 menu
F0
parameter
description
hidden
item
run
lock
out
F1 ACTIVE
FAULTS
DISPLAY
ACTIVE
FAULTS?
Contains a list of the active faults
N
N
RESET
ACTIVE
FAULTS?
Allows for reset of active faults
N
N
F2 FAULT
HISTORY
DISPLAY
FAULT
HISTORY?
Contains a list of up to the last sixteen faults
N
N
CLEAR
FAULT
HISTORY?
Allows for the clearing of the fault history
N
N
Detailed Descriptions
The FAULTS F0 menu does not access settable
parameters; instead, it provides a means of
examining the drive’s active faults and the fault
history.
This menu also allows for clearing of active
faults in order to get the drive ready to return to
operation after a fault shutdown.
ACTIVE FAULTS
(Active Faults)
This sub-menu contains a list of the active faults.
This sub-menu also allows the user to reset the
active faults.
Active Faults List
The active fault list displays and records the
active faults. The faults will remain on the fault
list until a fault reset is initiated.
Press the enter key to enter the active fault list.
Use the up and down arrow keys to scroll
through the active faults.
Resetting Active Faults
The Reset Active Faults function allows the user
to initiate a fault reset via the digital operator,
regardless of the setting of the Fault Reset
Source parameter. (see section 3.5.1)
•
While the Digital Operator display shows:
RUN/FAULT
SUB MENU
DATA ENT
HPV OPERATOR
DISPLAY ACTIVE
F1 FAULTS?
RUN/FAULT
SUB MENU
DATA ENT
HPV OPERATOR
ACTIVE FAULTS
F1 CHARGE FAULT
RUN/FAULT
SUB MENU
DATA ENT
HPV OPERATOR
FAULTS F0
ACTIVE FAULTS F1