Terminals
28
Remember when servicing the
HPV 600: Hazardous voltages
may exist in the drive circuits
even with drive circuit breaker in
off position.
IMPORTANT: Use extreme
caution: Do not touch any circuit
board, the drive, or motor
electrical connections without
making sure that the unit is
properly grounded and that no
high voltage is present.
NEVER attempt maintenance
unless:
•
the incoming three phase
power (460 or 230VAC) is
disconnected and locked out.
•
also, ensure the DC Bus
charge light is out.
•
even with the light out, we
recommend that you use a
voltmeter between (N) and
(P) to verify that no voltage is
present.
CAUTION: Before continuing,
ensure the DC Bus Charge LED
is not illuminated.
IMPORTANT: Take ESD
precautions, devices within the
drive are sensitive to static
damage.
Incremental Encoder Option Card
Incremental Encoder
Option Card
(installed in option port #1)
Grounding Screw
(attached with
metal stand-off)
Plastic Stand-off
Encoder
Connection
Terminals
Encoder Connection Terminals
Pins 61-68