![background image](http://html1.mh-extra.com/html/magnetek/hpv-600/hpv-600_technical-manual_3605624031.webp)
Interconnections
31
Details
Logic Inputs
The HPV 600’s nine programmable logic inputs
are opto-isolated. The inputs become “true” by
closing contacts or switches between the logic
input terminal and voltage source common (or
voltage source). The voltage supply for the logic
inputs is 24VDC.
IMPORTANT
Internal 24VDC power supply has a capacity of
100 mA
The choices for the voltage source common (or
voltage source) depend on if the user is using an
external voltage supply or using the internal
voltage supply.
Sinking Logic Inputs (Internal Supply)
Sourcing Logic Inputs (Internal Supply)
16
17
18
19
20
21
22
23
24
15
13
14
1
TB1
logic input 1
logic input 2
logic input 3
logic input 4
logic input 5
logic input 6
logic input 7
logic input 8
logic input 9
logic input+24VDC or common
+24VDC isolated
+24VDC iso. common
shield
16
17
18
19
20
21
22
23
24
15
13
14
1
TB1
logic input 1
logic input 2
logic input 3
logic input 4
logic input 5
logic input 6
logic input 7
logic input 8
logic input 9
logic input+24VDC or common
+24VDC isolated
+24VDC iso. common
shield
Содержание HPV 600
Страница 1: ...HPV 600 AC Elevator Drive Technical Manual...
Страница 162: ......