![background image](http://html1.mh-extra.com/html/magnetek/hpv-600/hpv-600_technical-manual_3605624005.webp)
Specifications
5
Drive Specifications
Power Ratings
•
208/230 Volt AC input:
7.5, 10, 15, and 20 HP (North American)
•
460 Volt AC input:
10, 15, 20, and 25 HP (North American)
•
400 Volt AC input:
4, 5.5, 7.5, 11, and 15 kW (European)
•
150% of continuous current rating
for 60 seconds
•
200% of continuous current rating
for 5 seconds
Input Power
•
Nominal Voltage Levels:
- 200-240 VAC, 3-phase, ± 10%
(North American)
- 380-480 VAC, 3-phase, ± 10%
(North American)
- 380-440 VAC, 3-phase –15,+10%
(European)
•
Frequency: 48 - 63 Hz
•
Line Impedance: 3% without choke / 1%
with choke
Output Power
•
Voltage: 0 - Input Voltage
•
Frequency: 0 - 120 Hz
•
Carrier Frequency: 2.5 kHz - 16 kHz
Digital Inputs
•
Nine (9) programmable opto-isolated
logic inputs.
•
Voltage: 24VDC (internal or external)
•
Internal 24VDC power supply:
200-250mA*capacity (do not exceed 250mA)
* except for –4011 and –4015
which have a 100mA capacity
•
Sinking Current: 9 mA
•
Scan Rate: 2 msec.
•
Update Rate: 4 msec.
Digital Outputs
Two (2) programmable Form-C relays.
•
2A at 30VDC / 250VAC (inductive load)
•
Update Rate: 2 msec.
Four (4) programmable opto-isolated open
collectors.
•
Voltage: 50 Volts DC (max.)
•
Capacity: 150 mA
•
Update Rate: 2 msec.
Analog Input
One differential input.
•
Voltage: ± 10 Volts DC
•
Resolution: 12 Bit
•
Software gain and offset available
•
Update Rate: 2 msec.
Analog Outputs
with optional analog output option card
Two (2) programmable differential outputs.
•
Voltage: ± 10 Volts DC
•
Capacity: 10 mA
•
Resolution: 12 Bit
•
Update Rate: 2 msec.
Encoder Feedback
with optional incremental encoder option card
•
Supply Voltage:
12VDC or 5VDC
•
Capacity:
150mA
•
PPR:
600 - 10,000
•
Maximum Frequency:
300 kHz
•
Input:
2 channel quadrature
5 or 12 volts dc differential
(A, /A, B, /B)
Design Features
•
DC Bus Choke: Connections for optional
external DC Bus Choke*
* except for –4034, –4039, and –2060
which have an external DC Bus Choke
•
Internal Dynamic Brake IGBT: Connections
for external Dynamic Brake Resistor
Environmental
•
Operating ambient air temperature range -
10°C (14°F) to 50°C (120°F)
•
Altitude 1000m (3300 ft) without derating
•
Relative humidity 95% (non-condensing)
•
Environment: protected from corrosive
gases; conductive dust
•
Vibration: 0.5g
Standards
•
CSA (North American Models)
Содержание HPV 600
Страница 1: ...HPV 600 AC Elevator Drive Technical Manual...
Страница 162: ......
Страница 163: ......