Closed-loop Logic Inputs C2
114
Configure C0 menu
Logic Inputs C2 submenu
C2
parameter
description
default
hidden
item
run
lock
out
LOGIC INPUT 1
logic input #1
DRIVE ENABLE
Y
Y
LOGIC INPUT 2
logic input #2
RUN
Y
Y
LOGIC INPUT 3
logic input #3
FAULT RESET
Y
Y
LOGIC INPUT 4
logic input #4
UP/DWN
Y
Y
LOGIC INPUT 5
logic input #5
S-CURVE SEL 0
Y
Y
LOGIC INPUT 6
logic input #6
STEP REF B0
Y
Y
LOGIC INPUT 7
logic input #7
STEP REF B1
Y
Y
LOGIC INPUT 8
logic input #8
STEP REF B2
Y
Y
LOGIC INPUT 9
logic input #9
EXTRN FAULT 1
Y
Y
choices
contact cfirm
Auxiliary contacts from motor contactor.
drive enable
Must be asserted to permit drive to run. This does not initiate run, just permits
initiation.
extrn fault 1
User input fault #1
extrn fault 2
User input fault #2
extrn fault 3
User input fault #3
extrn /flt 4
User input fault #4
fault reset
Asserting this input attempts to reset faults.
low gain sel
Low gain for the speed regulator is chosen when this input is asserted.
mech brake hold
Auxiliary contacts from mechanical brake. Asserted when brake is in hold mode.
mech brake pick
Auxiliary contacts from mechanical brake. Asserted when brake is picked (lifted).
no function
Input not assigned
ospd test src
Asserting input, applies the overspeed multiplier to the speed command for the next
run.
pre-trq latch
Transition from false to true latches pre torque command.
run
If drive is enabled through the DRIVE ENABLE logic input, this function will start
drive operation.
run down
If drive is enabled through the DRIVE ENABLE logic input, this function will start
drive operation with negative speed commands.
run up
If drive is enabled through the DRIVE ENABLE logic input, this function will start
drive operation with positive speed commands.
s-curve sel 0
Bit 0 of S-curve selection
s-curve sel 1
Bit 1 of S-curve selection
ser2 insp ena
defines one of the two sources of inspection run command
(only serial mode 2)
step ref b0
Bit 0 of multi-step speed command selection
step ref b1
Bit 1 of multi-step speed command selection
step ref b2
Bit 2 of multi-step speed command selection
step ref b3
Bit 3 of multi-step speed command selection
trq ramp down
Asserting this ramps torque output to zero at “Ramped Stop Time parameter” rate.
up/dwn
This logic can be used to change the sign of the speed command.
false = no inversion, true = inverted.