STANDARD CONTROL/DISPLAY OPERATION
44
t E S t
Green LED Lit
5) Press the
DATA/FCTN key to exit the
PCU parameter measurement routine and
return to the "Function" level. The SCDU
displays:
9 9 7
Both LEDs Off
6) After completion of SELF-TUNE, enable
Function 2. (Unless using manual entry)
Power Conversion Diagnostics
The drive has built-in diagnostic routines that
can be performed via the SCDU. The PCU
diagnostic routines are able to test for four
failure modes. The first test that the PCU
performs is a test of the three line fuses.
Assuming the three line fuses are all OK, the
PCU then performs a test for shorted SCRs/
doubler packs. If this test indicates no
shorted SCRs/doublers, the PCU then verifies
that less than 5% of the value entered for
“Rated Field Current” is attainable. The PCU
then tests for open SCRs by passing current
through the forward bridge followed by the
reverse bridge, and finally checks polarity of
voltage feedback. The result of the test is
displayed on the SCDU after the test
completes. The SCDU will light certain
unique LED patterns on its display
corresponding with the failure (see displays in
the procedure that follows). The Fault Codes
F910 (Blown Fuse), F911 (Shorted SCR),
F912 (Open SCR), and F917 (Reverse
Armature Feedback Wires) will not appear on
the SCDU if the Error Disposition List is
programmed so that they are not reported to
the Fault List.
WARNING
Armature current is circulated through the
armature circuit during parts of the PCU
Diagnostics Function. The PCU will reduce
the field current to zero on motors with a
shunt field in order to minimize motor rotation.
However, a PERMANENT MAGNET motor
must have its shaft locked mechanically prior
to running the PCU Diagnostics routine. If the
PCU detects significant motor voltage during
the test, the PCU Diagnostics Function will
abort.
The process for accessing the PCU
Diagnostics Function is as follows:
1) Use the
▲
and
▼
keys to select
Function 998 from the function level. The two
colored LEDs remain off during this step.
9 9 8
Both LEDs Off
2) Press the DATA/FCTN key to enter the
"Data" level for Function # 998. The green
LED is now lit to indicate that this function is
currently being accessed. The SCDU
prompts the user to press the ENTER key by
displaying:
E n t r
Green LED Lit
3) Press the ENTER key to actually start the
PCU diagnostics. While the PCU is per-
forming the Function 998 Diagnostics test, the
SCDU displays:
t E S t
Green LED Lit
The PCU will not begin the diagnostic routines
if a SEVERE PCU FAULT exists. The PCU
Содержание DSD 412
Страница 1: ...DSD 412 DC Elevator Drive Technical Manual CS00407 rev 06...
Страница 6: ...6...
Страница 102: ...MAINTENANCE 102 Figure 24 Connector and E prom Locations...
Страница 103: ...MAINTENANCE 103 Figure 25 Test Point Locations...
Страница 115: ...OUTLINE DRAWING 100A 115 Figure 26 Drive Chassis Outline DSD 412 100 Amp...
Страница 116: ...OUTLINE DRAWING 190A 116 Figure 27 Drive Chassis Outline DSD 412 195 Amp...
Страница 117: ...OUTLINE DRAWING 300A 117 Figure 28 Drive Chasis Outline DSD 412 300 Amp...
Страница 118: ...LAYOUT DRAWING 100A 118 Figure 29 Layout DSD 412 100 Amp A3 A1 A2 A2 L1 NEG GND L2 L3 POS...
Страница 119: ...LAYOUT DRAWING 195A 119 Figure 30 Layout DSD 412 195 Amp A3 A1 A2 A2...
Страница 120: ...LAYOUT DRAWING 300A 120 Figure 31 Layout DSD 412 300 Amp A3 A1 A2 A2...
Страница 121: ......