STANDARD CONTROL/DISPLAY OPERATION
36
Both LEDs Off
where the leading ‘F’ indicates a fault and the
3 digits following the ‘F’ indicate the fault
number. If however, there are no faults
present, the SCDU displays the normal
power-up message:
P - U
P
Both LEDs Off
This ‘P-UP’ display will remain on the SCDU
until a key is pressed or a fault occurs.
After Power-Up
After the drive has powered up and the SCDU
display is showing ‘P-UP’ or a fault number, it
can be used to enter new parameters, monitor
drive operation, and/or perform certain drive
diagnostics.
Every operation that the SCDU
can perform is called a ‘function’.
There may
be up to 1000 functions defined within the
DCU.
All SCDU functions have at least 2 levels, and
some functions use 3 levels. The two colored
LEDs below the lower left corner of the 4-1/2-
digit display are used to indicate which level of
a particular function the SCDU is currently at.
The top level of the SCDU operation is called
the "Function" level.
The two colored LEDs
are off when the SCDU is in the "Function"
level.
The
▲
or
▼
keys are used to select a
function number to be accessed while at this
level. The
▲
key increments the function
number in the display while the
▼
key
decrements it. The SCDU will ramp the
displayed function number when the
▲
or
▼
key is pressed and held for 1/2 second or
longer.
The DATA/FCTN key is used to toggle
between the “Data” level and the “Function”
level. Press the DATA/FCTN key when the
desired function number is in the display. At
this point, the SCDU leaves the "Function"
level and enters the "Data" level. Note that
the green LED is now lit. This operation is
consistent for every function on the SCDU,
although the data actually displayed while the
LED is GREEN is function-number specific.
Examples of every type of SCDU function are
given in subsequent sections. All function
numbers are shared between the SCDU and
the PCDU (Portable Control/Display Unit).
There are some functions, however, that can
only be performed with the PCDU. When
such a function number is selected on the
SCDU and the DATA/FCTN key is pressed,
the SCDU’s display will change to:
P c d u
Both LED’s Off
Changing Parameter Functions
SCDU functions are used to modify and/or
display setup points that the drive needs for
operation. Items that would typically fall into
this category are functions such as Accel
Times, Regulator Gains, Rated Speed and
any other parameters. The following steps
show how to modify a given parameter via the
SCDU display.
1) Use the
▲
and
▼
keys to select the
function number to be accessed. The two
colored LEDs remain off during this step. For
example, if #040 is chosen:
4 0
Both LEDs Off
2) Press the DATA/FCTN key to enter the
"Data" level for this function number. The
green LED is lit to indicate that the number
being shown is the current actual value for
this parameter. For example, if function 40 is
currently set for a value of 10.6, it will be
displayed as:
1 0. 6
Содержание DSD 412
Страница 1: ...DSD 412 DC Elevator Drive Technical Manual CS00407 rev 06...
Страница 6: ...6...
Страница 102: ...MAINTENANCE 102 Figure 24 Connector and E prom Locations...
Страница 103: ...MAINTENANCE 103 Figure 25 Test Point Locations...
Страница 115: ...OUTLINE DRAWING 100A 115 Figure 26 Drive Chassis Outline DSD 412 100 Amp...
Страница 116: ...OUTLINE DRAWING 190A 116 Figure 27 Drive Chassis Outline DSD 412 195 Amp...
Страница 117: ...OUTLINE DRAWING 300A 117 Figure 28 Drive Chasis Outline DSD 412 300 Amp...
Страница 118: ...LAYOUT DRAWING 100A 118 Figure 29 Layout DSD 412 100 Amp A3 A1 A2 A2 L1 NEG GND L2 L3 POS...
Страница 119: ...LAYOUT DRAWING 195A 119 Figure 30 Layout DSD 412 195 Amp A3 A1 A2 A2...
Страница 120: ...LAYOUT DRAWING 300A 120 Figure 31 Layout DSD 412 300 Amp A3 A1 A2 A2...
Страница 121: ......