Input / Output Verification
99
Input – Output Signal Verification
The Control Display Unit (CDU) function #981 may be used to directly read and track the status of
logic input and output signals at DSD 412 drive terminals. This is an easy way to verify the
integrity of input and output logic signals to the drive. Refer to specific connection diagrams for
your application to confirm the definition of how each signal is being used. The I/O indicator
technique as described below will work regardless of whether or not the particular terminals and
signals are used by internal software logic or actually wired into your application. Function #981
does not work with the Portable Control display Unit.
Here’s how to use this valuable troubleshooting tool:
1. Press the Up
▼
or Down
▲
keys and go to F#981.
2. Press the DATA FCTN KEY. The green light should turn ON to indicate that data is being
displayed.
3. Segments on the local Control Display Unit will light up to indicate active input and output logic
actions. Vertical segments represent input signals and horizontal segments represent output
signals as identified below.
Figure 23: I/O Monitor Function
E-STOP
TB3(6)
TB1(53)
TB1(7)
TB1(12)
TB1(49)
TB1(54)
TB1(8)
TB1(50)
TB1(9)
THRMST
TB3(8)
TB1(51)
TB1(10)
TB1(11)
TB1(40,41,42)
TB1(79)
TB1(38-39)
TB1(83)
TB1(36-37)
TB1(84)
TB1(78)
LPR
TB3(5)
I N P U T L O G I C D A T A B I T S
O U T P U T L O G I C D A T A B I T S
N-A
N-A
N-A
N-A
N-A
N-A
N-A
N-A
TB1(52)
Содержание DSD 412
Страница 1: ...DSD 412 DC Elevator Drive Technical Manual CS00407 rev 06...
Страница 6: ...6...
Страница 102: ...MAINTENANCE 102 Figure 24 Connector and E prom Locations...
Страница 103: ...MAINTENANCE 103 Figure 25 Test Point Locations...
Страница 115: ...OUTLINE DRAWING 100A 115 Figure 26 Drive Chassis Outline DSD 412 100 Amp...
Страница 116: ...OUTLINE DRAWING 190A 116 Figure 27 Drive Chassis Outline DSD 412 195 Amp...
Страница 117: ...OUTLINE DRAWING 300A 117 Figure 28 Drive Chasis Outline DSD 412 300 Amp...
Страница 118: ...LAYOUT DRAWING 100A 118 Figure 29 Layout DSD 412 100 Amp A3 A1 A2 A2 L1 NEG GND L2 L3 POS...
Страница 119: ...LAYOUT DRAWING 195A 119 Figure 30 Layout DSD 412 195 Amp A3 A1 A2 A2...
Страница 120: ...LAYOUT DRAWING 300A 120 Figure 31 Layout DSD 412 300 Amp A3 A1 A2 A2...
Страница 121: ......