DRIVE SETUP AND ADJUSTMENT
59
Note 4: When Progressive Speed Select
mode is used, any combination of S0-S4 not
shown in Table will result in zero speed being
selected.
Note 5. When Reference Mode Select
(
function
110) is set for Analog or Serial
velocity reference control, inputs S0-S4 have
no affect.
Function #170
Accel #1 Time
Units: SEC
Range: 0.50 – 15.0
Default: 5.00
Total acceleration time in seconds for S-curve
ramp #1 to occur from zero speed to rated
elevator speed. Effective only when internal
pre-set speeds are used.
Function #171
Accel #2 Time
Units: SEC
Range: 0.50 – 15.0
Default: 5.00
Total acceleration time in seconds for S-curve
ramp #2 to occur from zero speed to rated
elevator speed. Effective only when internal
pre-set speeds are used.
Function #172
Decel #1 Time
Units: SEC
Range: 0.50 – 15.0
Default: 5.00
Total deceleration time in seconds for S-curve
ramp #1 to occur from rated speed to zero
speed. Effective only when internal pre-set
speeds are used.
Function #173
Dec #2 Time
Units: SEC
Range: 0.50 – 15.0
Default: 5.00
Total deceleration time in seconds for S-curve
ramp #2 to occur from rated speed to zero
speed. Effective only when internal pre-set
speeds are used.
Function #174
Accel #1 %S
Units: %
Range: 0.1 – 100.0
Default: 25.0
The percent of time that will be spent in the
controlled jerk or S-portion of the timed ramp
curve during ramped acceleration #1. A
percent S of 0.1% corresponds to almost all
linear acceleration. A percent S of 100% will
make the S-curve #1 smooth with no linear
acceleration portion. Effective only when
internal pre-set speeds are used.
Function #175
Accel #2 %S
Units: %
Range: 0.1 – 100.0
Default: 25.0
The percent of time that will be spent in the
controlled jerk or S-portion of the timed ramp
curve during ramped acceleration #2. A
percent S of 0.1% corresponds to almost all
linear acceleration. A percent S of 100% will
make the S-curve #1 smooth with no linear
acceleration portion. Effective only when
internal pre-set speeds are used.
Function #176
Decel #1 %S
Units: %
Range: 0.1 – 100.0
Default: 25.0
The percent of time that will be spent in the
controlled jerk or S-portion of the timed ramp
curve during ramped deceleration #1. A
percent S of 0.1% corresponds to almost all
linear deceleration. A percent S of 100% will
make the S-curve #1 smooth but with no
linear deceleration portion. Effective only
when internal pre-set speeds are used.
Function #177
Decel #2 %S
Units: SEC
Range: 0.1 – 100.0
Default: 25.0
The percent of time that will be spent in the
controlled jerk or S-portion of the timed ramp
curve during ramped deceleration #2. A
percent S of 0.1% corresponds to almost all
linear deceleration. A percent S of 100% will
make the S-curve #2 smooth with no linear
deceleration portion. Effective only when
internal pre-set speeds are used.
Function #178
Accel #3 Time
Units: SEC
Range: 0.50 – 15.00
Default 5.00
Total acceleration time in seconds for S-curve
ramp #3 to occur from zero speed to rated
Содержание DSD 412
Страница 1: ...DSD 412 DC Elevator Drive Technical Manual CS00407 rev 06...
Страница 6: ...6...
Страница 102: ...MAINTENANCE 102 Figure 24 Connector and E prom Locations...
Страница 103: ...MAINTENANCE 103 Figure 25 Test Point Locations...
Страница 115: ...OUTLINE DRAWING 100A 115 Figure 26 Drive Chassis Outline DSD 412 100 Amp...
Страница 116: ...OUTLINE DRAWING 190A 116 Figure 27 Drive Chassis Outline DSD 412 195 Amp...
Страница 117: ...OUTLINE DRAWING 300A 117 Figure 28 Drive Chasis Outline DSD 412 300 Amp...
Страница 118: ...LAYOUT DRAWING 100A 118 Figure 29 Layout DSD 412 100 Amp A3 A1 A2 A2 L1 NEG GND L2 L3 POS...
Страница 119: ...LAYOUT DRAWING 195A 119 Figure 30 Layout DSD 412 195 Amp A3 A1 A2 A2...
Страница 120: ...LAYOUT DRAWING 300A 120 Figure 31 Layout DSD 412 300 Amp A3 A1 A2 A2...
Страница 121: ......