99
NOTES
•
Be sure to check, before actual work, that the boom automatically stops at the set angle. If the
boom does not automatically stop, reset the boom angle in the above steps.
•
An alarm sounds intermittently when the boom, which is in the upper limit, is in the prediction zone or
upper limit stop state and only if the raising operation is performed, and when the boom, which is in the
lower limit, is in the prediction zone or lower limit stop state and only if the lowering operation is
performed.
•
The set value is memorized when the starter switch is turned to the "OFF" position.
When the boom is in the prediction zone or upper limit stop state in a condition in which the boom
angle upper limit or lower limit is set, the monitor display illuminates in orange.
[Cancel]
Press the switch in a condition in which the upper limit value or lower limit value is set. The orange
display section can be selected in white frame. Each time the switch is pressed, the selection
changes. After selection, press and hold the switch. The monitor display changes to the black color
and the upper limit value or lower limit value setting is canceled.
3. Working radius upper limit switch
Use this switch to set or cancel the upper limit value of the
working radius.
[Setting]
Set the boom to the desired working radius in a condition in
which no upper limit value is set, and press and hold the
switch.
The upper limit value on the monitor display changes to the
orange color and the working radius is set as the upper limit
value.
NOTES
•
Be sure to check, before actual work, that the boom automatically stops at the set working
radius. If the boom does not automatically stop, reset the working radius in the above steps.
•
When the boom is in the prediction alarm zone or upper limit stop state, an alarm sounds
intermittently only if lowering operation or extension operation is performed.
•
The set value is memorized when the starter switch is turned to the "OFF" position.
When the boom is in the prediction zone or upper limit stop state in a condition in which the working
radius upper limit is set, the monitor display illuminates in orange.
[Cancel]
Press and hold the switch in a condition in which the upper limit value is set. The monitor display
changes to the black color and the upper limit value or lower limit value setting is canceled.
4. Setting check/canceling switch
(1) Setting check
Use this switch to check all the set values set in the above
sections 1 - 3.
•
Press this switch.
All the set values set in the above sections 1 - 3 are
displayed for about 5 seconds.
The boom angle upper limit is displayed in the boom length.
Содержание CC1485S-1
Страница 2: ......
Страница 57: ...49 SAFETY LABEL LOCATIONS OUTSIDE OF THE CABIN...
Страница 58: ...50 SAFETY LABEL LOCATIONS IN THE ENGINE ROOM...
Страница 59: ...51 1 Safe operation 557 3494500 2 Working range diagram 585 2236900...
Страница 82: ...74...
Страница 232: ...224 This Page Intentionally Left Blank...
Страница 267: ...259...
Страница 302: ...294 This Page Intentionally Left Blank...
Страница 305: ...297 2 SPECIFICATION DIMENSIONAL DRAWING...
Страница 309: ...301 4 WORKING RADIUS LIFTING HEIGHT...
Страница 310: ...302 This Page Intentionally Left Blank...
Страница 363: ...355 9 2 SPECIFICATION DIMENSIONAL DRAWING...
Страница 365: ...357 9 4 WORKING RADIUS LIFTING HEIGHT 9 4 1 WORKING RADIUS LIFTING HEIGHT WHEN FLY JIB ANGLE IS 0 DEGREES AND 20 DEGREES...
Страница 366: ...358 9 4 2 WORKING RADIUS LIFTING HEIGHT WHEN FLY JIB ANGLE IS 40 DEGREES AND 60 DEGREES...
Страница 368: ......
Страница 369: ......
Страница 370: ......