measurement chamber and trigger an alarm.
In areas for which the smoke detector V2 is not suited (e.g. warmer than
45°C/113F or colder than -10°C/14F) such as not isolated attics, cold store, or
boiler rooms.
In areas that are hardly accessible or have very high ceilings (for testing and
disabling the alarm).
Installing the smoke detector:
1.
Choose a place of installation according to “place of
installation”.
2.
Use the bracket (4) as a template to drill the required holes
in your ceiling.
3.
Install the bracket with the included screws at your ceiling.
Make sure that the attachment hooks (5) face downwards.
4.
Connect the installation notches (3) to the attachment hooks
(5). By pressing and turning the smoke detector clockwise,
you fix it to the mount.
Tampering
The smoke detector V2 has a tampering protection. This is located in the
installation notches (3).
The tampering contact is closed when the installation hooks (5) lock into the
installation notches (3).
If the tampering contact is opened, the LED of the smoke detector lights up
briefly.
The alarm panel receives a notification about the open tampering contact
o
An error is displayed in the status section and the alarm panel regularly
emits a notification sound.
o
If the alarm panel is armed, a tampering alarm is triggered.
o
In case “tampering alarm” is set to “always”, a tampering alarm is also
triggered in disarm mode.
Connecting the smoke detector V2 and putting it into operation
1.
After inserting the batteries, you hear two brief signals and the LED begins to
flash. During the warm-up phase of six minutes, you can connect the smoke
detector V2 with your alarm panel.
2.
Open the main menu of the alarm panel.
3.
Open the menu “Sensors”
“Add”.
4.
Click “Start”.
5.
Press the learn button of the smoke detector V2. Two brief signals are emitted.
6.
The alarm panel will confirm the successful addition with a brief signal tone and
display the smoke detector V2 in the menu “Sensors”
”Add.” Click on next
to the listed sensor to finish the connection process.
Please note:
The smoke detector V2 should be installed immediately after the batteries are
Содержание XT 1 Plus
Страница 1: ...Manual version 1 3 Firmware 0 0 3 0K XT 1 Plus XT2 Plus XT3 Alarm panel User Manual ...
Страница 37: ...37 ...
Страница 133: ...133 Using the assistant 1 Follow the instructions of the app and click on continue 2 Select which alarm panel you have ...
Страница 329: ...329 Remarks ...
Страница 330: ...330 Remarks ...
Страница 331: ...331 Remarks ...
Страница 332: ...332 Remarks ...