196
Connecting the glass breaking sensor V2 and putting it into operation
6.
Open the housing of the glass breaking sensor V2.
7.
Insert the battery.
8.
Open the main menu of the alarm panel.
9.
Open the menu “Sensors”
“Add”.
10.
Click “Start”.
11.
Press the learn button of the glass breaking sensor V2 briefly.
12.
The alarm panel will confirm the successful addition with a brief signal tone
and display the glass breaking sensor in the menu “Sensors”
”Add”. Click
on next to the listed sensor to finish the connection process.
Range test:
10.
Open the alarm panel menu “Sensors”
“Range” and press “Start”.
11.
Press the learn button for ten seconds.
12.
The sensor and the signal strength should be indicated. The higher the indicated
number the better the reception (1-9).
Please note:
If the signal strength at the place of installation is below 4, we advise to use a wireless
repeater, since it is normal that the signal strength may fluctuate for 2-3 points, thus,
a signal loss is possible.
Battery:
The glass breaking sensor V2 requires a 3V CR123A lithium battery. The alarm panel will
inform you when the battery is running low. We advise you to discharge any residual
current before inserting the new battery. In order to do that, press the learn button a few
times after removing the old battery.
DIP Switch:
The two DIP switches allow you to adjust the sensitivity of the glass breaking sensor V2.
Sensitivity
Dip switch 1
Dip switch 2
Range
Maximum
OFF
OFF
8m (8.7 yards)
Medium
OFF
ON
5m (5.4 yards)
Low
ON
OFF
3m (3.2 yards)
Minimum
ON
ON
1.5m (1.6 yards)
Test mode:
In order to activate the test mode of the glass breaking sensor V2 for five minutes,
simply press the learn button.
During the test mode, you can use a test device (glass breaking simulator) to check if
the glass breaking sensor V2 is in range of your windows without triggering an alarm of
the alarm panel. A successful test is signalled by the red and green LED.
Содержание XT 1 Plus
Страница 1: ...Manual version 1 3 Firmware 0 0 3 0K XT 1 Plus XT2 Plus XT3 Alarm panel User Manual ...
Страница 37: ...37 ...
Страница 133: ...133 Using the assistant 1 Follow the instructions of the app and click on continue 2 Select which alarm panel you have ...
Страница 329: ...329 Remarks ...
Страница 330: ...330 Remarks ...
Страница 331: ...331 Remarks ...
Страница 332: ...332 Remarks ...