233
red status LED lights up
2.
Disarm:
User PIN (default 1234) + Disarm button. Two audio signals are emitted and
the blue status LED lights up.
3.
Activate Home mode:
User PIN (default 1234) + Home and then 1, 2, or 3 to activate the required
home mode. Three audio signals are emitted and the red status LED flashes four
times. If you do not press any number after the Home button, home mode 1 is
automatically activated.
Relay output
The outdoor keypad has a potential-free output (10). The relay output can be configured
as required and control external devices, e.g. turn on a lamp, activate the alarm input of
a camera to start a recording.
1.
Start the installer mode by entering the installer PIN of the keypad (default 0000)
and then pressing the * button. The power LED lights up orange.
2.
Press * + 0 to start the relay configuration. The status LED lights up additionally
and a brief audio signal is audible.
3.
There are eight different modes to configure the relay. Enter one of the following
inputs (1-8 and possibly input 2):
Input 1
(one long beep)
Input 2
(one long beep)
Relay response upon
arming
Relay response upon
disarming
Note
1
----
Open
Closed
2
----
Closed
Open
(Default setting)
3
1 ~ 99 + #
Open
Closed for 1 - 99 seconds
4
1 ~ 99 + #
Closed
Open for 1 - 99 seconds
5
1 ~ 99 + #
Closed for 1 - 99 seconds
Open
6
1 ~ 99 + #
Open for 1 - 99 seconds
Closed
Input 1
(one long beep)
Input 2
(one long beep)
Relay response to
keypad
activation
Relay response to
keypad going to
standby
mode
Note
7
----
Open
Closed
Operates
independently of
status changes of
the alarm system
8
----
Closed
Open
4.
The status LED goes off and the settings are saved in the keypad.
5.
Exit the installation mode by pressing the Disarm button twice.
Example 1:
Start the relay configuration mode and activate the fourth mode (button 4). The outdoor
keypad emits a long confirmation sound. Exit the installation mode by pressing the
disarm button
twice. The relay will closed when the alarm panel is armed and will
opened when the alarm panel is disarmed.
Example 2:
Start the relay configuration mode and activate the fourth mode (button 4). Enter a
number between 1 and 99 and press the # button afterwards in order to define how long
the relay shall be opened after the alarm panel is disarmed. Exit the installation mode
by pressing the disarm button
twice. The relay will open after the alarm panel is
disarmed for the defined time (1 – 99 seconds). After this time, or if the alarm panel is
Содержание XT 1 Plus
Страница 1: ...Manual version 1 3 Firmware 0 0 3 0K XT 1 Plus XT2 Plus XT3 Alarm panel User Manual ...
Страница 37: ...37 ...
Страница 133: ...133 Using the assistant 1 Follow the instructions of the app and click on continue 2 Select which alarm panel you have ...
Страница 329: ...329 Remarks ...
Страница 330: ...330 Remarks ...
Страница 331: ...331 Remarks ...
Страница 332: ...332 Remarks ...