Detailed operation by function groups
252
The response time must be checked after each parameter adjustment.
E.g.) Check the response after adjusting CON_02 – Check the response after
adjusting CON_03
Option
CON_02
Note1)
CON_03 CON_04
Description
To speed up the
response
Slower
Faster
Slower
The respond times speed up, but the system
is unstable, and the motor vibration and
overshoot are increased.
To slow down
the response
Faster
Slower
Faster
Motor vibration and overshoot are
decreased, but the response times speed
down.
Note 1) Displayed only when the operation mode (PAR_07) is set to “Speed (PM).”
6.6.4 Overshoot Prevention
This function prevents the motor’s feedback speed from overshooting.
overshoot prevention gain (CON_09)
If a value other than ‘0’ is set at CON_09, the overshoot prevention function is
active. The overshoot rate for motor feedback speed varies based on the
motor’s inertia set at (PAR_57).
Code
Keypad display Name
Range
Unit
Default setting
CON_09
ASR FF Gain
Overshoot prevention gain
0–1000
%
0
Содержание LSLV-L100 Series
Страница 16: ...3 Preparing the Installation Preparation ...
Страница 36: ...Installing the Inverter 23 Installation Power terminal and control terminal wiring diagram ...
Страница 240: ...Detailed operation by function groups 227 Operation Details BX time FUN_51 set to a value other than 0 ...
Страница 252: ...Detailed operation by function groups 239 Operation Details stops When forward operation has a lighter load ...
Страница 339: ...326 Communication features CAN message frame versions CAN 2 0A CAN 2 0B ...
Страница 395: ...382 ...