Installing the Inverter
17
In
stal
lati
on
Follow the instructions that follow when connecting the grounding, mains
power, and control cables to the terminal blocks. For cable specifications,
refer to
on page
Step 2 Ground connection
Remove the front cover. Then, follow the instructions below to connect the
inverter’s ground cable.
Locate the ground terminal and connect an appropriately rated ground cable
to the terminals. Refer to
on page
correct grounding cable for your installation.
Note
•
Connect the ground cables to the ground terminals. Do not connect the
ground cables to the inverter’s case bolts.
•
Use cables with as large cross-sectional area as possible for grounding.
Ground cables must meet or exceed the specifications listed in the 1.5
Cable selection on page 8. Keep the ground cable as short as possible and
ground termination as close as possible to the inverter.
Connect the other end of all ground cable to an earth (ground) terminal.