Detailed operation by function groups
221
O
p
er
ati
o
n
D
etai
ls
For example, for a multistep operation of 2 speeds (500 and 1,500 rpm), if
acceleration time is set to 5 seconds, the operation can be illustrated as shown
in the figure below.
6.5.7.2 S-curve acceleration/deceleration pattern 1–2 (FUN_36–
39)
Acceleration/deceleration gradient level patterns can be configured to enhance
and smooth the inverter’s acceleration and deceleration curves. While linear
pattern features a linear increase or decrease to the output frequency, at a fixed
rate, an S-curve pattern provides a smoother and more gradual increase or
decrease of output frequency, ideal for lift-type loads or elevator doors, etc.
Acceleration/deceleration patterns can be defined by the parameter settings
listed in the following table. Codes FUN_36–FUN_39 define the curvature.
Codes FUN_36 and FUN_37are for acceleration, while FUN_38, FUN_39 are
for deceleration.
Code
Keypad display Name
Range
Unit
Default setting
FUN_36
Acc S Start
S-curve rate at acceleration 1
0.0–50.0
%
0.0
FUN_37
Acc S End
S-curve rate at acceleration 2
0.0–50.0
%
0.0
FUN_38
Dec S Start
S-curve rate at deceleration 1
0.0–50.0
%
0.0
FUN_39
Dec S End
S-curve rate at deceleration 2
0.0–50.0
%
0.0
Содержание LSLV-L100 Series
Страница 16: ...3 Preparing the Installation Preparation ...
Страница 36: ...Installing the Inverter 23 Installation Power terminal and control terminal wiring diagram ...
Страница 240: ...Detailed operation by function groups 227 Operation Details BX time FUN_51 set to a value other than 0 ...
Страница 252: ...Detailed operation by function groups 239 Operation Details stops When forward operation has a lighter load ...
Страница 339: ...326 Communication features CAN message frame versions CAN 2 0A CAN 2 0B ...
Страница 395: ...382 ...