Table of functions
108
Code
Comm
addr.
Name
Keypad
display
Range
Unit
Default
setting
IM
V
\F
Sl
ip
PM
EL
IM
EL
P
M
Page
FUN_45 752D
Accelerati
on time 3
Acc
Time-3
0.00–600.0
sec
4.00
○
○
○
○
○
○
FUN_46 752E
Decelerati
on time 3
Dec
Time-3
0.00–600.0
sec
4.00
○
○
○
○
○
○
FUN_47 752F
Accelerati
on time 4
Acc
Time-4
0.00–600.0
sec
5.00
○
○
○
○
○
○
FUN_48 7530
Decelerati
on time 4
Dec
Time-4
0.00–600.0
sec
5.00
○
○
○
○
○
○
FUN_51 7533
Emergen
cy stop
decelerati
on time
BX Time 0.0–6000.0
sec
0.0
○
○
○
○
x x 226
FUN_52 7534
Emergen
cy stop
terminal
filter time
BX
Termi
LPF
0.0–2000
ms
5.0
○
○
○
○
○
○
FUN_53 7535
Motor
pre-
excitation
time
PreExct
Time
0–10000
ms
0
○
x x x x x 228
FUN_54 7536
Hold time
at zero-
speed
Hold
Time
10–10000
ms
1000
○
x x
○
x x 228
FUN_56 7538
Short
floor
operation
speed
ShortFlr
Spd
0.0–PAR_11
rpm/
Hz
0.0
○
○
○
○
x x 230
FUN_57 7539
Short
floor
operation
ShortFlr
Time
0.00–100.00 sec
0.00
○
○
○
○
x x 230
Содержание LSLV-L100 Series
Страница 16: ...3 Preparing the Installation Preparation ...
Страница 36: ...Installing the Inverter 23 Installation Power terminal and control terminal wiring diagram ...
Страница 240: ...Detailed operation by function groups 227 Operation Details BX time FUN_51 set to a value other than 0 ...
Страница 252: ...Detailed operation by function groups 239 Operation Details stops When forward operation has a lighter load ...
Страница 339: ...326 Communication features CAN message frame versions CAN 2 0A CAN 2 0B ...
Страница 395: ...382 ...