Detailed operation by function groups
208
The following table lists the type and setting for multifunction analog outputs.
Output types
Description
Output signal level
Ai1 Value
Analog input value
+10 V: 10 V
Ai2 Value
Analog input value
+10 V: 20 mA
PreRamp Ref
Speed command before
acceleration/deceleration
+10 V: MaxSpeed
PostRamp Ref
Speed command after
acceleration/deceleration
+10 V: MaxSpeed
ASR Inp Ref
Speed controller input
command
+10 V: MaxSpeed
Output Freq
Output frequency
+10 V: MaxSpeed
Motor Speed
Note1)
Motor speed
+10 V: MaxSpeed
Speed Dev
Note1)
Speed deviation
+10 V: Rated slip x 2
ASR Out
Note1)
Speed controller output
+10 V: 250%
Torque Bias
Note1)
Torque bias
+6 V: 150%
PosTrq Limit
Note1)
Forward torque limit
10 V: 250%
NegTrq Limit
Note1)
Reverse torque limit
10 V: 250%
RegTrq Limit
Note1)
Torque limit at regeneration
10 V: 250%
IqeRef
Note1)
Torque current reference
+10 V: 250% of the rated torque current
Iqe
Note1)
Torque current
+10 V: 250% of the rated torque current
Flux Cur Ref
Note2)
Recommended flux current
reference
10 V: Rated inverter current x 1
IdeRef
Note1)
Flux current reference
+10 V: Rated flux current x 2
Ide
Note1)
Flux current
+10 V: Rated flux current x 2
ACR_D Out
Note1)
D-axis current controller output +10 V: 600
ACR_Q Out
Note1)
Q-axis current controller
output
+10 V: 600
Содержание LSLV-L100 Series
Страница 16: ...3 Preparing the Installation Preparation ...
Страница 36: ...Installing the Inverter 23 Installation Power terminal and control terminal wiring diagram ...
Страница 240: ...Detailed operation by function groups 227 Operation Details BX time FUN_51 set to a value other than 0 ...
Страница 252: ...Detailed operation by function groups 239 Operation Details stops When forward operation has a lighter load ...
Страница 339: ...326 Communication features CAN message frame versions CAN 2 0A CAN 2 0B ...
Страница 395: ...382 ...