307
Communication features
C
o
m
m
u
n
icati
o
n
F
eatu
res
Read normal response
ACK
Station ID
CMD
Data
SUM
EOT
06h
‘01’–‘1F’
‘R’
‘XXXX’
‘XX’
04h
1 byte
2 bytes
1 byte
n + 4 bytes
2 bytes
1 byte
Total bytes = (7 x n x 4): 39 maximum
Read error response
NAK
Station ID
CMD
Error code
SUM
EOT
15h
‘01’-‘1F’
‘R’
‘**’
‘XX’
04h
1 byte
2 bytes
1 byte
2 bytes
2 bytes
1 byte
Total bytes = 9
7.3.3 Write protocol details
Write request
ENQ
Station ID
CMD
Address
Number of
addresses
Data
SUM
EOT
05h
‘01’–‘1F’
‘W’
‘XXXX’
‘1’–‘8’ = n
‘XXXX…’ ‘XX’
04h
1 byte
2 bytes
1 byte
4 bytes
1 byte
n x 4
bytes
2 bytes
1 byte
Total bytes = (12 + n x 4): 44 maximum
Write normal response
ACK
Station ID
CMD
Data
SUM
EOT
06h
‘01’–‘1F’
‘W’
‘XXXX…’
‘XX’
04h
1 byte
2 bytes
1 byte
n x 4 bytes
2 bytes
1 byte
Total bytes = (7 + n x 4): 39 maximum
Содержание LSLV-L100 Series
Страница 16: ...3 Preparing the Installation Preparation ...
Страница 36: ...Installing the Inverter 23 Installation Power terminal and control terminal wiring diagram ...
Страница 240: ...Detailed operation by function groups 227 Operation Details BX time FUN_51 set to a value other than 0 ...
Страница 252: ...Detailed operation by function groups 239 Operation Details stops When forward operation has a lighter load ...
Страница 339: ...326 Communication features CAN message frame versions CAN 2 0A CAN 2 0B ...
Страница 395: ...382 ...