Table of functions
80
5 Table of functions
5.1 Display (DIS) group
•
IM: Speed(IM), V/F: Speed ( V/F), Slip: Slip Compensation, PM: Speed (PM),
ELIM: EL+IM, ELPM: EL+PM
•
O: Displayed, X: Not displayed, #: Not available
•
On the Keypad, “#” indicates not available and “*” indicates a duplicate
setting.
Code
Comm
addr.
Name
Keypad
display
Range Unit
Default
setting
IM
V
\F
Sl
ip
PM
EL
IM
EL
P
M
Page
DIS_00 -
Speed
reference,
output
current,
operation
status,
output
frequency
DIS
▶
T/K
0.0A
00 STP
0.00Hz
DIS
▶
T/
K 0.0A
00 STP
0.00Hz
○
○
○
○
○
○
DIS_01 -
User define
1
Ai1 Value
%
Out
Volt
rms
○
○
○
○
○
○
Ai2 Value
%
○
○
○
○
○
○
PreRamp Ref
rpm/Hz
○
○
○
○
○
○
PostRamp Ref
rpm/Hz
○
○
○
○
○
○
ASR Inp Ref
rpm/Hz
○
○
○
○
○
○
Output Freq
rpm/Hz
○
○
○
○
○
○
Motor Speed
rpm
○
x
x
○
○
○
Speed Dev
rpm
○
x
x
○
○
○
SpdDev Max
rpm
○
x
x
○
○
○
SpdDev Time
Sec
○
x
x
○
○
○
ASR Out
%
○
x
x
○
○
○
Torque Bias
%
○
x
x
○
○
○
PosTrq Limit
%
○
x
x
○
○
○
NegTrq Limit
- %
○
x
x
○
○
○
RegTrq Limit
%
○
x
x
○
○
○