9. Basic functions
9-2
SV-iC5
Analog Frequency setting via Potentiometer (V0) on the Keypad
Used to prevent fluctuations in analog input signals caused by noise
Group
LED Display
Parameter Name
Set
Value
Min/Max
Range
Factory
Defaults
Unit
0.0 [Frequency
Command]
-
-
-
Hz
Drive
group
Frq
[Frequency Mode]
2
0/8 0
I 1
[Filter time constant for V0 input]
10
0/9999
10
I 2
[V0 input minimum voltage]
-
0/10
0
V
I 3
[Frequency corresponding to I2]
-
0/400
0.0
Hz
I 4
[V0 input max voltage]
-
0/10
10
V
I/O group
I 5
[Frequency corresponding to I4]
-
0/400
60.0
Hz
Set
Frq
– [Frequency Mode] to 2.
The set frequency can be monitored in
0.0
- [Frequency Command].
I 1 : [Filtering time constant for V0 input]
Effective for eliminating noise in the frequency setting circuit.
Increase the filter time constant if steady operation cannot be performed due to noise. A larger setting
results in slower response (t gets longer).
I 2 - I 5 : [Min/Max input voltage and corresponding frequency setting]
The corresponding frequency to V0 input voltage is settable.
Example:
When setting I 2 - [V0 input minimum voltage] = 2V, I 3- [Frequency corresponding to I 2]=
10Hz, I 4 - [V0 input max voltage] = 8V and I 5 - [Frequency corresponding to I 4]= 50Hz, the following
figure is shown.
Freq.
setting
V0 input
I 2
I 4
I 3
I 5
2V
8V
10Hz
50Hz
V0 input
Set freq
t
Содержание SV-iC5 Series
Страница 8: ...Table of Contents viii SV iC5 ...
Страница 22: ...3 Wiring 3 6 SV iC5 Notes ...
Страница 38: ...5 Programming keypad 5 14 SV iC5 Notes ...
Страница 42: ...6 Basic operation 6 4 SV iC5 Notes ...
Страница 64: ......
Страница 68: ......
Страница 108: ...10 Advanced functions 10 20 SV iC5 Notes ...
Страница 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes ...
Страница 136: ......