9. Basic functions
9-17
SV-iC5
Manual Torque Boost
Group
LED display
Parameter name
Set
Value
Min/Max
range
Factory
defaults
Unit
F27
[Torque boost select]
0
0/1 0
F28
[Torque boost in forward
direction]
Function
group 1
F29
[Torque boost in reverse
direction]
- 0/15
5 %
Set F27 to 0 {Manual torque boost}.
The values of [Torque boost in forward/reverse direction] are set separately in F28 and F29.
CAUTION
If the boost value is set much higher than required, it may cause motor overheating due to over-
energizing.
Auto Torque Boost
Group
LED Display
Parameter Name
Set
Value
Min/Max
Range
Factory
Defaults
Unit
Function
group 1
F27
[Torque boost select]
1
0/1 0
H34
[No Load Motor Current]
-
0.1/12 - A
H41
[Auto tuning]
0
0/1 0
Function
group 2
H42
[Stator resistance (Rs)]
-
0/5.0 -
Ω
Before Auto Torque Boost setting, H34 and H42 should be set correctly (See page 10-6, 10-8).
Set F27 to 1 {Auto torque boost}.
The inverter automatically boosts the output voltage by calculating torque boost value using motor parameters.
FX
Time
RX
Voltage
FX torque
boost
No torque boost
100%
RX torque
boost
Содержание SV-iC5 Series
Страница 8: ...Table of Contents viii SV iC5 ...
Страница 22: ...3 Wiring 3 6 SV iC5 Notes ...
Страница 38: ...5 Programming keypad 5 14 SV iC5 Notes ...
Страница 42: ...6 Basic operation 6 4 SV iC5 Notes ...
Страница 64: ......
Страница 68: ......
Страница 108: ...10 Advanced functions 10 20 SV iC5 Notes ...
Страница 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes ...
Страница 136: ......