9. Basic functions
9-1
SV-iC5
9. Basic Functions
9.1
Frequency
mode
Digital Frequency setting via Keypad 1
Group
LED Display
Parameter Name
Set
Value
Min/Max
Range
Factory
Defaults
Unit
0.0 [Frequency
Command] -
0/400 0.0
Hz
Drive
group
Frq
[Frequency mode]
0
0/8 0
Run frequency is settable in
0.0
- [Frequency Command].
Set
Frq
– [Frequency mode] to 0 {Frequency setting via Keypad 1}.
Set the desired frequency in
0.0
and press the Prog/Ent (
z
) key to enter the value into memory.
The value is settable not greater than
F21
– [Max frequency].
Digital Frequency setting via Keypad 2
Group
LED Display
Parameter Name
Set
Value
Min/Max
Range
Factory
Defaults
Unit
0.0 [Frequency
Command] -
0/400 0.0
Hz
Drive
group
Frq
[Frequency mode]
1
0/8 0
Run frequency is settable in
0.0
- [Frequency Command].
Set
Frq
– [Frequency mode] to 1{Frequency setting via Keypad 2}.
In
0.0
, frequency is changed upon pressing the Up (
S
)/Down (
T
) key. It is seleted to use the Up/Down key as
potentiometer on keypad.
The value is settable not greater than
F21
– [Max frequency].
Содержание SV-iC5 Series
Страница 8: ...Table of Contents viii SV iC5 ...
Страница 22: ...3 Wiring 3 6 SV iC5 Notes ...
Страница 38: ...5 Programming keypad 5 14 SV iC5 Notes ...
Страница 42: ...6 Basic operation 6 4 SV iC5 Notes ...
Страница 64: ......
Страница 68: ......
Страница 108: ...10 Advanced functions 10 20 SV iC5 Notes ...
Страница 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes ...
Страница 136: ......