5. Programming keypad
5-7
SV-iC5
5.5 Parameter setting method
Changing parameter value in Drive group
When changing ACC time from 5.0 sec to 16.0
Drive group
1
-. In the first code “0.0”, press the Up (
S
) key once to go to the second code.
2
-. ACC [Accel time] is displayed.
-. Press the Prog/Ent key (
z
) once.
3
-. Preset value is 5.
0
, and the cursor is in the digit
0
.
-. Press the Left (
W
) key once to move the cursor to the left.
4
-. The digit
5
in
5
.0 is active. Then press the Up (
S
) key once.
5
-. The value is increased to
6
.0
-. Press the Left (
W
) key to move the cursor to the left.
6
-.
0
.60 is displayed. The first
0
in
0
.60 is active.
-. Press the Up (
S
) key once.
7
-.
1
6.0 is set.
-. Press the Prog/Ent (
z
) key once.
-.
1
6.0 is blinking.
-. Press the Prog/Ent (
z
) key once again to return to the parameter name.
8
-.
ACC
is displayed.
Accel time
is changed from 5.0 to 16.0 sec.
♣
In step 7, pressing the Left
(
W
)
or Right
(
X
)
key while 16.0 is blinking will disable the setting.
Note) Pressing the Left (
W
)/ Right (
X
) /Up (
S
) /Down (
T
) key while cursor is blinking will cancel the parameter value
change.
Содержание SV-iC5 Series
Страница 8: ...Table of Contents viii SV iC5 ...
Страница 22: ...3 Wiring 3 6 SV iC5 Notes ...
Страница 38: ...5 Programming keypad 5 14 SV iC5 Notes ...
Страница 42: ...6 Basic operation 6 4 SV iC5 Notes ...
Страница 64: ......
Страница 68: ......
Страница 108: ...10 Advanced functions 10 20 SV iC5 Notes ...
Страница 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes ...
Страница 136: ......