9. Basic functions
9-5
SV-iC5
Frequency setting via Potentiometer on the 0-10V input
Group
LED Display
Parameter Name
Set
Value
Min/Max
Range
Factory
Defaults
Unit
0.0 [Frequency
Command]
- -
-
Hz
Drive
group
Frq
[Frequency Mode]
7
0/8 0
Set
Frq
– [Frequency Mode] to 7 {Potentiometer on the 0-10V input}.
Relative code: I 1 - I 5, I6 - I10
Refer to P 9-4 Frequency setting via potentiometer on the 0-20mA input for the setting.
Analog Hold
Group
LED Display
Parameter Name
Set
Value
Min/Max
Range
Factory
Defaults
Unit
Drive
group
Frq
[Frequency Mode]
2/7
0/8 0
I20
[Multi-function input terminal
P1 define]
- 0
~ ~
I/O group
I24
[Multi-function input Terminal
P5 Define]
23
0/24
4
This setting becomes activated when
Frq
– [Frequency Mode] is set to 2-7.
Set one of the Multi-function input terminals to 23 to activate Analog Hold operation.
When I24 –[Multi-function input terminal P5 define] is set to 23,
Freq.
P5
Run
command
Freq. setting
Содержание SV-iC5 Series