14. Specifications
14-1
SV-iC5
14. Specifications
14.1 Technical data
Input & output ratings
Model : SV xxx iC5 – 2x
004
008
015
022
[HP]
0.5 1 2 3
Max motor capacity
1
[kW] 0.4
0.75
1.5
2.2
Capacity [kVA]
2
0.95 1.9 3.0 4.5
FLA [A]
2.5
5
8
12
Frequency
0 ~ 400 [Hz]
3
Output
ratings
Voltage
Three Phase 200 ~ 230V
4
Voltage
Single Phase 200 ~ 230V (
±
10%)
Frequency
50 ~ 60 [Hz] (
±
5%)
Input
ratings
Current 5.5
9.2
16
21.6
Control
Control mode
V/F control, Sensorless vector control
Frequency setting resolution
Digital: 0.01Hz
Analog: 0.06Hz (Max. frequency : 60Hz)
Accuracy of Frequency command
Digital: 0.01% of Max. output frequency
Analog: 0.1% of Max. output frequency
V/F Ratio
Linear, Squared Pattern, User V/F
Overload capacity
Software: 150% for 60 s
Torque boost
Auto/Manual torque boost
Operation
Operation mode
Keypad/ Terminal/ Communication option selectable
Frequency setting
Analog: 0 ~ 10[V], 0 ~ 20[mA], Keypad Potentiometer
Digital : Keypad
Operation features
PID control, Up-Down operation, 3-wire operation
Input
Multi-function
terminal
NPN/ PNP selectable
Function: (refer to page 3-5)
Output
Multi-function open
collector terminal
Operating status
Function: (Refer to page 11-6)
1
Indicates the maximum applicable motor capacity when using a 4-pole LG Standard motor.
2
Rated capacity is based on 220V.
3
Max settable freq is 300Hz when H30 is set to 3 “Sensorless Vector Control”.
4
Max output voltage will not be greater than the input voltage. Output voltage less than the input voltage can be
programmed.
Содержание SV-iC5 Series
Страница 8: ...Table of Contents viii SV iC5 ...
Страница 22: ...3 Wiring 3 6 SV iC5 Notes ...
Страница 38: ...5 Programming keypad 5 14 SV iC5 Notes ...
Страница 42: ...6 Basic operation 6 4 SV iC5 Notes ...
Страница 64: ......
Страница 68: ......
Страница 108: ...10 Advanced functions 10 20 SV iC5 Notes ...
Страница 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes ...
Страница 136: ......