9. Basic functions
9-16
SV-iC5
User V/F pattern
Group
LED
display
Parametername
Set
value
Min/Max
range
Factory
defaults
Unit
F30
[V/F pattern]
2
0/2 0
F31
[User V/F frequency 1]
-
0/400
15.0
Hz
~ ~
Function
group 1
F38
[User V/F voltage 4]
-
0/100
100
%
Select F30 to 2 {User V/F}.
User can adjust the Volt/Frequency ratio according to V/F pattern of specialized motors and load
characteristics.
CAUTION
In case of using a standard induction motor, if this value is set much higher than linear V/F pattern,
it could result in torque shortage or motor overheating due to over-energizing.
When User V/F pattern is active, F28 - [Torque Boost in forward direction] and F29 - [Torque Boost
in reverse direction] are deactivated.
Output voltage adjustment
Group
LED Display
Parameter Name
Set
Value
Min/Max
Range
Factory
Defaults
Unit
Function
group 1
F39
[Output voltage
adjustment]
-
40/110 100
%
This function is used to adjust the output voltage of the inverter. This is useful when you use a motor that has
a rated voltage lower than the input voltage.
Freq.
Voltage
Start
freq.
F31
F33
F35
F37 Base
freq.
F32
F34
F36
F38
100%
Linear
V/F
Freq.
Voltage
Base freq.
100%
70%
100% setting
70% setting
Содержание SV-iC5 Series
Страница 8: ...Table of Contents viii SV iC5 ...
Страница 22: ...3 Wiring 3 6 SV iC5 Notes ...
Страница 38: ...5 Programming keypad 5 14 SV iC5 Notes ...
Страница 42: ...6 Basic operation 6 4 SV iC5 Notes ...
Страница 64: ......
Страница 68: ......
Страница 108: ...10 Advanced functions 10 20 SV iC5 Notes ...
Страница 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes ...
Страница 136: ......