5. Programming keypad
5-11
SV-iC5
How to monitor Motor rpm in Drive group when the motor is rotating in 1730 rpm.
Drive group
1
-. Present run frequency can be monitored in the first code of Function group 1. The
preset frequency is 57.6Hz.
-. Continue pressing the Up (
S
) /Down (
T
) key until rPM is displayed.
2
-. Motor rpm can be monitored in this code.
-. Press the Prog/Ent (
z
) key once.
3
-. Last three digits
730
in 1
730
rpm is shown on the LED.
-. Press the Left (
W
) key once.
4
-. First three digits
173
in 1730 rpm are shown on the LED.
-. Press the Prog/Ent (
z
) key once.
5
-. Return to the rPM code.