9. Basic functions
9-6
SV-iC5
9.2 Multi-Step frequency setting
Group
LED Display
Parameter Name
Set
Value
Min/Max
Range
Factory
Defaults
Unit
0.0 [Frequency
command] 5.0
0/400 0.0
Hz
Frq [Frq
mode]
0
0/8
0
-
St1
[Multi-Step frequency 1]
- 10.0
St2
[Multi-Step frequency 2]
- 20.0
Drive
group
St3
[Multi-Step frequency 3]
-
0/400
30.0
Hz
I22
[Multi-function input
terminal P3 define]
5
2 -
I23
[Multi-function input
terminal P4 define]
6
3 -
I24
[Multi-function input
terminal P5 define]
7
0/24
4 -
I30
[Multi-Step frequency 4]
-
30.0
I31
[Multi-Step frequency 5]
-
25.0
I32
[Multi-Step frequency 6]
-
20.0
I/O group
I33
[Multi-Step frequency 7]
-
0/400
15.0
Hz
Select a terminal to give Multi-step frequency command among P1-P5 terminals.
If terminals P3-P5 are selected for this setting, set I22-I24 to 5-7 to give Multi-step frequency command.
Multi-step frequency 0 is settable using
Frq
– [Frequency mode] and
0.0
– [Frequency command].
Multi-step frequency 1-3 are set at St1-St3 in Drive group, while Step frequency 4-7 are set at I30-I33 in I/O
group.
Step
freq
FX or RX
P5
P4
P3
0
- - -
1
- -
2
-
-
3
-
4
- -
5
-
6
-
7
Frequency
P3
P4
P5
FX
RX
Step 0
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 0
Содержание SV-iC5 Series
Страница 8: ...Table of Contents viii SV iC5 ...
Страница 22: ...3 Wiring 3 6 SV iC5 Notes ...
Страница 38: ...5 Programming keypad 5 14 SV iC5 Notes ...
Страница 42: ...6 Basic operation 6 4 SV iC5 Notes ...
Страница 64: ......
Страница 68: ......
Страница 108: ...10 Advanced functions 10 20 SV iC5 Notes ...
Страница 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes ...
Страница 136: ......