11. Monitoring
11-1
SV-iC5
11. Monitoring
11.1 Operating status monitoring
Output current
Group
LED Display
Description
Set
value
Min/Max
range
Factory
default
Unit
Drive group
CUr
Output current
-
Inverter output current can be monitored in Cur.
Motor RPM
Group
LED Display
Description
Set
value
Min/Max
range
Factory
default
Unit
Drive group
rPM
[Motor RPM]
-
H31
[Number of motor poles]
-
2/12
4
H40 [Control
mode
select]
-
0/2
0
Function
group 2
H74
[Gain for Motor rpm display]
-
1/1000
100 %
Motor rpm can be monitored in rPM.
When H40 is set to 0 {V/F control} or 1 {PID control}, the Inverter output frequency (f) is displayed in
RPM using the formula below. Motor slip is not considered.
H31 : Enter the number of rated motor poles on the nameplate.
H74 : This parameter is used to change the motor speed display to rotating speed
(r/min) or mechanical speed (m/mi).
Inverter DC Link Voltage
Group
LED Display
Parameter Name
Set
value
Min/Max
range
Factory
default
Unit
Drive group
dCL
[Inverter DC Link Voltage]
-
Inverter DC link voltage can be monitored in dCL.
2
times the value of input voltage is displayed while motor is at a stop.
It is the voltage detected between P1 and N terminal of power terminal.
100
74
31
120
H
H
f
RPM
×
×
=
Содержание SV-iC5 Series
Страница 8: ...Table of Contents viii SV iC5 ...
Страница 22: ...3 Wiring 3 6 SV iC5 Notes ...
Страница 38: ...5 Programming keypad 5 14 SV iC5 Notes ...
Страница 42: ...6 Basic operation 6 4 SV iC5 Notes ...
Страница 64: ......
Страница 68: ......
Страница 108: ...10 Advanced functions 10 20 SV iC5 Notes ...
Страница 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes ...
Страница 136: ......