5. Programming keypad
5-9
SV-iC5
Changing parameter values in Function 1, 2 and I/O group
When changing the parameter value of F 27 from 2 to 5
Function
group 1
1
-. In F0, press the Prog/Ent (
z
) key once.
2
-. Check the present code number.
-. Increase the value to 7 by pressing the Up (
S
) key.
3
-. When 7 is set, press the Left (
W
) key once.
4
-.
0
in
0
7 is active.
-. Increase the value to 2 by pressing the Up (
S
) key.
5
-.
2
7 is displayed
-. Press the Prog/Ent (
z
) key once.
6
-. The parameter number F27 is displayed.
-. Press the Prog/Ent (
z
) key once to check the set value.
7
-. The set value is 0.
-. Increase the value to 1 by pressing the Up (
S
) key.
8
-. Press the Prog/Ent (
z
) key once.
9
-. F27 is displayed after 5 stops blinking. Changing parameter value has been complete.
-. Press the either Left (
W
) or Right (
X
) key once to go to the first code.
10
-. Return to F0.
♣
The above setting is also applied to change parameter values in function group 2 and I/O group.