Indoor unit
Ceiling Cassette 4-way
_
5
Indoor Units
2. Specifications
* Model Name
A:Basic, C:Plasma
Type
Model
Unit
Cooling Capacity kW
kcal/h
Btu/h
Heating Capacity kW
kcal/h
Btu/h
Casing
Dimensions Body mm
(WxHxD) inch
Front Panel mm
inch
Coil Rows x Columns x FPI
Face Area m
2
Fan Type
Motor Outputx Number W
Running Current A
Air Flow Rate(H / M / L) CMM
cfm
Drive
Motor type
Temperature Control
Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material
Safety Device
Pipe Liquid Side mm(inch)
Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm(inch)
Net Weight Body kg(lbs)
Noise Level (Sound Press, 1.5m, H / M / L) dB(A)
Power Supply
Ø, V, Hz
Refrigerant Control
Transmission cable mm
2
Panel Color
Panel Name(Accessory)
Elevation Grill(Accessory)
ARNU30GTP*4
9.0
7,700
30,700
10.0
8,600
34,100
Galvanized Steel Plate
840 x 204 x 840
33-1/16 x 8-1/32 x 33-1/16
950 x 25 x 950
37-13/32 x 31/32 x 37-13/32
2 x 8 x 19
0.4
Turbo Fan
30
0.15
24.3 / 22.8 / 19.5
858 / 805 / 688
Direct
BLDC
Foamed polystrene
Fuse
Ø9.52(3/8)
Ø15.88(5/8)
25(1)
20.8(45.8)
40 / 36 / 33
1, 220-240, 50
1, 220, 60
EEV
CVV-SB 1.0~1.5 X 2C
Morning fog
PT-UMC(1)
PTEGM0
ARNU36GTN*4
10.6
9,100
36,200
11.9
10,200
40,600
Galvanized Steel Plate
840 x 246 x 840
33-1/16 x 9-11/16 x 33-1/16
950 x 25 x 950
37-13/32 x 31/32 x 37-13/32
2 x 10 x 19
0.57
Turbo Fan
135
0.56
25 / 21 / 19
883 / 742 / 671
Direct
BLDC
Foamed polystrene
Fuse
Ø9.52(3/8)
Ø15.88(5/8)
25(1)
23.5(51.8)
43 / 40 / 37
1, 220-240, 50
1, 220, 60
EEV
CVV-SB 1.0~1.5 X 2C
Morning fog
PT-UMC(1)
PTEGM0
ARNU42GTM*4
12.3
10,600
42,000
13.8
11,000
43,800
Galvanized Steel Plate
840 x 288 x 840
33-1/16 x 11-11/32 x 33-1/16
950 x 25 x 950
37-13/32 x 31/32 x 37-13/32
2 x 12 x 19
0.57
Turbo Fan
135
0.56
30 / 27 / 24
1,059 / 954 / 848
Direct
BLDC
Foamed polystrene
Fuse
Ø9.52(3/8)
Ø15.88(5/8)
25(1)
25.6(56.4)
44 / 41 / 38
1, 220-240, 50
1, 220, 60
EEV
CVV-SB 1.0~1.5 X 2C
Morning fog
PT-UMC(1)
PTEGM0
4 Way Ceiling Cassette
Notes:
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics”
chapter should be considered for electrical work and design. Especially the power cable and circuit breaker
should be selected in accordance with that.
5. EEV: Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60