Indoor unit
10. Installation
ARTCOOL (Mirror)
_
27
Indoor Units
Wrap the insulation material
around the connecting portion.
1. Overlap the connection pipe insulation material
and the indoor unit pipe insulation material.
Bind them together with vinyl tape so that there
may be no gap.
2. Set the tubing cutting line upward.
Wrap the area which accommodates the rear
piping housing section with vinyl tape.
3. Bundle the piping and drain hose together by
wrapping them with vinyl tape sufficient enough
to cover where they fit into the rear piping hous-
ing section. Be sure that the drain hose is locat-
ed at the lowest side of the bundle. Locating at
the upper side can cause overflow from the
drain pan through the inside of the unit.
Insulation material
Vinyl tape(narrow)
Connection pipe
Connecting cable
Vinyl tape (wide)
Wrap with vinyl tape
Indoor unit pipe
Pipe
Gas Pipe
Liquid Pipe
Cutting Line
Cutting Line
Good Case
Bad Case
* Tubing cutting line have to be upward.
Wrap with vinyl tape
Drain hose
Pipe
Vinyl tape(wide)
If the drain hose is routed inside the room insulate
the hose with an insulation material* so that drip-
ping from sweating condensation) will not damage
furniture or floors.
* Foamed polyethylene or equivalent is
recommended.