Страница 4: ...cts data computer software and services have been developed exclusively at private expense and are sold to governmental entities as commercial items as defined by 48 C F R 2 101 with limited and restricted rights to use reproduction and disclosure LIMITED AND RESTRICTED RIGHTS NOTICE If products data computer software or services are delivered pursuant a General Services Administration GSA contrac...

Страница 5: ... messages 29 Troubleshooting tables 49 EasyStartup problems 49 DVD drive problems 50 General problems 51 Hard disk drive problems 51 Intermittent problems 52 Keyboard mouse or pointing device problems 52 Memory problems 54 Microprocessor problems 55 Monitor or video problems 55 Optional device problems 57 Power problems 58 Serial port problems 59 Software problems 60 Universal Serial Bus USB port ...

Страница 6: ...g a DVD drive 142 Installing a DVD drive 142 Removing a tape drive 144 Installing a tape drive 145 Removing a hot swap hard disk drive 146 IDs for hot swap hard disk drives 147 Installing a hot swap hard disk drive 148 Removing a simple swap hard disk drive 150 Installing a simple swap hard disk drive 151 Power and signal cables for internal drives 151 Replacing an adapter 152 Removing an adapter ...

Страница 7: ...176 Installing the front adapter retention bracket 176 Replacing the hot swap power supply cage 177 Removing the hot swap power supply cage 177 Installing the hot swap power supply cage 177 Replacing a hot swap power supply 178 Removing a hot swap power supply 178 Installing a hot swap power supply 179 Replacing a non hot swap power supply 180 Removing a non hot swap power supply 180 Installing a ...

Страница 8: ...btaining the IP address for the IMM 264 Logging on to the Web interface 265 Enabling the Intel Gigabit Ethernet Utility program 265 Configuring the Gigabit Ethernet controllers 265 Enabling and configuring Serial over LAN SOL 266 UEFI update and configuration 266 Appendix Notices 267 Trademarks 268 Important notes 268 Product recycling and disposal 269 Compliance with Republic of Turkey Directive ...

Страница 9: ... available at http www lenovo com support Before servicing a Lenovo product be sure to read the Safety Information See Important Safety Information For information about the terms of the warranty and getting service and assistance see the Warranty and Support Information document Important Safety Information Be sure to read all caution and danger statements in this book before performing any of th...

Страница 10: ...is labeled Statement 1 translations for that caution statement are in the Safety Information document under Statement 1 Be sure to read all caution and danger statements in this document before you perform the procedures Read any additional safety information that comes with the server or optional device before you install the device Attention Use No 26 AWG or larger UL listed or CSA certified tel...

Страница 11: ...when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed otherwise in the installation and configuration procedures v Connect and disconnect cables as described in the following table when installing moving or opening covers on this product or attached devices T...

Страница 12: ...it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not v Throw or immerse into water v Heat to more than 100 C 212 F v Repair or disassemble Dispose of the battery as required by local ordinances or regulations 4 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maint...

Страница 13: ... v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded Class 3A or Class 3B laser diode Note the following Laser radiation when open Do not stare into the beam do not view directly with optical instruments and avoid direct exposure to the beam Class 1 Laser Product ...

Страница 14: ...power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all power cords are disconnected from the power source 1 2 6 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...

Страница 15: ...zardous Substances in Electrical and Electronic Equipment Directive 2002 95 EC is a European Union legal requirement affecting the global electronics industry RoHS requirements must be implemented on Lenovo products placed on the market and sold in the European Union after June 2006 Products on the market before June 2006 are not required to have RoHS compliant parts If the parts are not compliant...

Страница 16: ...sub to RoHS RoHS Must be RoHS Note A direct substitution is a part with a different FRU part number that is automatically shipped by the distribution center at the time of order Turkish statement of compliance The Lenovo product meets the requirements of the Republic of Turkey Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment EEE Türkiye...

Страница 17: ...server management capabilities The IMM provides remote server management through industry standard interfaces Intelligent Platform Management Interface IPMI version 2 0 Simple Network Management Protocol SNMP version 3 Common Information Model CIM Web browser v Remote presence capability and blue screen capture The remote presence feature provides the following functions Remotely viewing video wit...

Страница 18: ...ur 3 5 inch hot swap hard disk drives With the hot swap feature you can add remove or replace hard disk drives without turning off the server v Large system memory capacity The server supports up to 24 GB of system memory when registered DIMMs are installed The server supports up to 8 GB of memory when unbuffered DIMMs are installed The memory controller supports error correcting code ECC and non ...

Страница 19: ...IMMs 32 GB using registered DIMMs RDIMMs v Types PC3 8500 or PC3 10600R 999 single rank or double rank 1066 and 1333 MHz ECC DDR3 registered or unbuffered SDRAM DIMMs only v Connectors Six dual inline memory module DIMM connectors two way interleaved v Supports 1 GB 2 GB and 4 GB when available unbuffered DIMMs 1 GB 2 GB 4 GB and 8 GB when available registered DIMMs SATA optical drives v UltraSlim...

Страница 20: ... management optional features in use 2 The sound levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute ANSI S12 10 and ISO 7779 and are reported in accordance with ISO 9296 Actual sound pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise ...

Страница 21: ...or the error might be in a microprocessor or in a microprocessor socket See Microprocessor problems on page 55 for information about diagnosing microprocessor problems v Before you run the diagnostic programs you must determine whether the failing server is part of a shared hard disk drive cluster two or more servers that share external storage devices If it is part of a cluster you can run all di...

Страница 22: ... diagnostic programs see Running the diagnostic programs on page 67 If you receive an error see Diagnostic messages on page 68 If the diagnostic programs were completed successfully and you still suspect a problem see Solving undetermined problems on page 110 Diagnosing a problem Before you contact Lenovo or an approved warranty service provider follow these procedures in the order in which they a...

Страница 23: ... not listed installing the update might solve the problem b Check for and correct an incorrect configuration If the server is incorrectly configured a system function can fail to work when you enable it if you make an incorrect change to the server configuration a system function that has been enabled can stop working 1 Make sure that all installed hardware and software are supported See http www ...

Страница 24: ...e problem use the procedure for another symptom if possible To locate troubleshooting procedures for your server complete the following steps Note Changes are made periodically to the Lenovo Web site The actual procedure might vary slightly from what is described in this document 1 Go to http www lenovo com support 2 From the Select your product list select Servers and Storage 3 In the Browse by p...

Страница 25: ...he major components of the server and are stored in integrated USB memory The diagnostic programs collect the following information about the server System configuration Network interfaces and settings Installed hardware Service processor status and configuration Vital product data firmware and UEFI configuration Hard disk drive health RAID controller configuration Controller event logs including ...

Страница 26: ...r on self test or POST Note This server does not use beep codes for server status If a power on password is set you must type the password and press Enter when prompted for POST to run If POST detects a problem an error message is displayed See POST error codes on page 21 for more information 18 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...

Страница 27: ...cates a deassertion event when the event is no longer occurring v Integrated management module IMM event log This log contains a superset of IMM POST and system management interrupt SMI information that is in the system event log You can only access the event log through the IMM Web interface For more information see Event logs v DSA log This log is generated by the Dynamic System Analysis DSA Pre...

Страница 28: ...reboot is installed restart the server and press F2 to start DSA Preboot and view the event logs v If DSA Preboot is not installed insert the DSA Preboot CD and restart the server to start DSA Preboot and view the event logs v Alternatively you can restart the server and press F1 to start the Setup Utility and view the POST event log or system event log For more information see Viewing event logs ...

Страница 29: ...microprocessor and install a new microprocessor Restart the server If the error is corrected the old microprocessor is bad and must be replaced 3 Replace the following components one at a time in the order shown restarting the server each time a Trained service technician only Microprocessor b Trained service technician only System board 0011000 Invalid microprocessor type 1 Update the server firm...

Страница 30: ... memory test reseat the DIMMs 2 Remove and replace any DIMM for which the associated error LED is lit see Replacing a memory module on page 134 3 Run the Setup utility to enable all the DIMMs 4 Run the DSA Preboot memory test see Running the diagnostic programs on page 67 0051006 DIMM mismatch detected Make sure that the DIMMs match and are installed in the correct sequence see Replacing a memory ...

Страница 31: ...ver after each pair until a pair fails Replace the DIMMs in the failed pair with identical known good DIMMs restarting the server after each DIMM is installed Replace the failed DIMM Repeat this step until you have tested all removed DIMMs 4 Trained service technician only Replace the system board 0058008 DIMM failed memory test 1 Reseat the DIMMs and then restart the server 2 Replace the followin...

Страница 32: ... If possible rearrange the order of the adapters in the PCI slots to change the load order of the optional device ROM code 2 Run the Setup utility select Startup Options and change the boot priority to change the load order of the optional device ROM code 3 Run the Setup utility and disable some other resources if their functions are not being used to make more space available a Select Startup Opt...

Страница 33: ...ge Information only The backup switch was used to boot the secondary bank 3048006 Booted secondary backup UEFI image because of ABR 1 Run the Setup utility select Load Default Settings and save the settings to recover the primary UEFI settings 2 Turn off the server and remove it from the power source 3 Reconnect the server to the power source then turn on the server 305000A RTC date time is incorr...

Страница 34: ...on restored to default settings Information only This is message is usually associated with the CMOS battery clear event 3138002 Boot configuration error 1 Remove any recent configuration changes made to the Setup utility 2 Run the Setup utility select Load Default Settings and save the settings 3808000 IMM communication failure 1 Remove power from the server for 30 seconds and then reconnect the ...

Страница 35: ...t Settings and save the settings 2 Trained service technician only Replace the system board 3818002 Core Root of Trust Measurement CRTM update aborted 1 Run the Setup utility select Load Default Settings and save the settings 2 Trained service technician only Replace the system board 3818003 Core Root of Trust Measurement CRTM flash lock failed 1 Run the Setup utility select Load Default Settings ...

Страница 36: ...004 AEM power capping disabled 1 Check the settings and the event logs 2 Make sure that the Active Energy Manager feature is enabled in the Setup utility Select System Settings Power Active Energy Capping Enabled 3 Update the server firmware to the latest level see Updating the firmware on page 258 4 Update the IMM firmware to the latest level see Updating the firmware on page 258 System event log...

Страница 37: ...ted Reduce the ambient temperature Numeric sensor Planar 3 3V going low lower critical has asserted Error A lower critical sensor going low has asserted Trained service technician only Replace the system board Numeric sensor Planar 3 3V going high upper critical has asserted Error An upper critical sensor going high has asserted Trained service technician only Replace the system board Numeric sens...

Страница 38: ...ode levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 2 Run the DSA program for the hard disk drives and other I O devices 3 Trained service technician only Replace microprocessor n n microprocessor number An Over Temperature Condition has been detected on the Processo...

Страница 39: ... technician only Replace microprocessor n n microprocessor number The Processor CPU nStatus has a Configuration Mismatch n microprocessor number Error A processor configuration mismatch has occurred 1 Make sure that the installed microprocessor is compatible see Specifications on page 11 for information about microprocessor requirements 2 Trained service technician only Replace the incompatible mi...

Страница 40: ...or number Sensor CPU nOverTemp has transitioned to non recoverable from a less severe state n microprocessor number Error A sensor has changed to Nonrecoverable state from a less severe state 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Mak...

Страница 41: ...etely closed 2 Make sure that the heat sink for microprocessor n is installed correctly 3 Trained service technician only Replace microprocessor n n microprocessor number A bus timeout has occurred on system 1 1 CIM_ComputerSystem ElementName Error A bus timeout has occurred 1 Remove the adapter from the PCI slot that is indicated by a lit LED 2 Replace the extender card 3 Remove all PCI adapters ...

Страница 42: ...nated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 2 Trained service technician only Replace the system board A Uncorrectable Bus Error has occurred on system 1 1 CIM_ComputerSystem ElementName Error A bus uncorrectable error has occurred Sensor Critical Int PCI 1 Check the system even...

Страница 43: ...portant Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 5 Trained service technician only Replace the system board A Uncorrectable Bus Error has occurred on system 1 1 CIM_ComputerSystem ElementName Error A bus uncorrectab...

Страница 44: ...ster solution before you update the code 5 Trained service technician only Replace the system board Sensor RAID Error has transitioned to critical from a less severe state Error A sensor has changed to Critical state from a less severe state 1 Check the hard disk drive LEDs 2 Reseat the hard disk drive for which the status LED is lit 3 Replace the defective hard disk drive The Drive n Status has b...

Страница 45: ...ndicated by a lit error LED Note You do not have to replace DIMMs by pairs 3 Run the Setup utility to enable all the DIMMs 4 Run the DSA memory test Memory Logging Limit Reached for DIMM All DIMMs on Memory Subsystem All DIMMs Error The memory logging limit has been reached 1 Update the server firmware to the latest level Important Some cluster solutions require specific code levels or coordinated...

Страница 46: ...y Subsystem One of the DIMMs Error A DIMM configuration error has occurred Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology Memory uncorrectable error detected for DIMM n Status on Memory Subsystem DIMM n Status n DIMM number Error A memory uncorrectable error has occurred 1 If the server failed the POST memory test reseat the DIMMs 2 Repl...

Страница 47: ...r Error A sensor has changed to Critical state from a less severe state 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 If a fan has failed complete the action for a fan failure 3 Replace DIMM n n DIMM number A PCI PERR has occurred on syste...

Страница 48: ... coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Remove the adapter from slot n 5 Replace the PCIe adapter 6 Replace extender card n n PCI slot number A PCI PERR has occurred on system 1 1 CIM_ComputerSystem ElementName Error A PCI PERR has occurred Sensor One of PCI Err 1 C...

Страница 49: ...ns require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Remove both adapters 5 Replace the PCIe adapter 6 Replace the extender card 7 Trained service technician only Replace the system board Fault in slot System board on system 1 1 CIM_ComputerSyst...

Страница 50: ...as been imported into the IMM The imported certificate must contain a public key that corresponds to the key pair that was previously generated by the Generate a New Key and Certificate Signing Request link 1 Make sure that the certificate that you are importing is correct 2 Try importing the certificate again Ethernet Data Rate modified from 1 to 2 by user 3 1 CIM_EthernetPort Speed 2 CIM_Etherne...

Страница 51: ...M_StaticIPAssignmentSettingData IPAddress 3 user ID Info A user has modified the IP address of the IMM No action information only IP subnet mask of network interface modified from 1 to 2 by user 3s 1 CIM_IPProtocolEndpoint SubnetMask 2 CIM_StaticIPAssignmentSettingData SubnetMask 3 user ID Info A user has modified the IP subnet mask of the IMM No action information only IP address of default gatew...

Страница 52: ... ID 1 had 2 login failures from CLI at 3 1 user ID 2 MaximumSuccessiveLoginFailures currently set to 5 in the firmware 3 IP address xxx xxx xxx xxx Error A user has exceeded the maximum number of unsuccessful login attempts from the command line interface and has been prevented from logging in for the lockout period 1 Make sure that the correct login ID and password are being used 2 Have the syste...

Страница 53: ... CIM_StaticIPSettingData DefaultGatewayAddress Info An IMM IP address and configuration have been assigned using client data No action information only LAN Ethernet 0 interface is no longer active Info The IMM Ethernet interface has been disabled No action information only LAN Ethernet 0 interface is now active Info The IMM Ethernet interface has been enabled No action information only DHCP settin...

Страница 54: ...e code Running the backup IMM main application Error The IMM has resorted to running the backup main application Update the IMM firmware Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code Please ensure that the IMM ...

Страница 55: ...stics v Integrated service processor No action information only Flash of 1 from 2 failed for user 3 1 CIM_ManagedElement ElementName 2 Web or LegacyCLI 3 user ID Info An attempt to update a firmware component from the interface and IP address has failed Try to update the firmware again The Chassis Event Log CEL on system 1 is 75 full 1 CIM_ComputerSystem ElementName Info The IMM event log is 75 fu...

Страница 56: ... must be performed only by a trained service technician Security Userid 1 had 2 login failures from an SSH client at IP address 3 1 user ID 2 MaximumSuccessiveLoginFailures currently set to 5 in the firmware 3 IP address xxx xxx xxx xxx Error A user has exceeded the maximum number of unsuccessful login attempts from SSH and has been prevented from logging in for the lockout period 1 Make sure that...

Страница 57: ...nents are field replaceable units FRU v If an action step is preceded by Trained service technician only that step must be performed only by a Trained service technician v Go to the Lenovo support Web site at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a request for information Symptom Action The EasyStartup DVD will not start v Mak...

Страница 58: ...or the DVD drive 2 Run the DVD drive diagnostic programs 3 Reseat the DVD drive cable 4 Replace the following components one at a time in the order shown restarting the server each time a DVD drive cable b DVD drive c Trained service technician only System board A CD or DVD is not working correctly 1 Clean the CD or DVD 2 Run the DVD drive diagnostic programs 3 Reseat the DVD drive cable 4 Reseat ...

Страница 59: ... by a Trained service technician v Go to the Lenovo support Web site at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a request for information Symptom Action Not all drives are recognized by the hard disk drive diagnostic test the Fixed Disk Test Remove the drive that is indicated by the diagnostic tests then run the hard disk drive ...

Страница 60: ...see Event logs on page 19 Keyboard mouse or pointing device problems v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved v See Chapter 7 Parts listing TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 on page 201 to determine which components are customer replaceable units CRU and which components are field replaceable units F...

Страница 61: ...ation hints tips and new device drivers or to submit a request for information Symptom Action The mouse or pointing device does not work 1 Make sure that v The mouse or pointing device cable is securely connected to the server v The mouse or pointing device drivers are installed correctly v The server and the monitor are turned on v The mouse option is enabled in the Setup utility program 2 If you...

Страница 62: ...ancy v The memory modules are seated correctly v You have installed the correct type of memory v All DIMMs are enabled The server might have automatically disabled a DIMM when it detected a problem 2 Check the POST error log for error message 289 v If a DIMM was disabled by a system management interrupt SMI replace the DIMM 3 Run memory diagnostics see Running the diagnostic programs on page 67 4 ...

Страница 63: ...tor or video problems Some monitors have their own self tests If you suspect a problem with your monitor see the documentation that comes with the monitor for instructions for testing and adjusting the monitor If you cannot diagnose the problem call for service v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved v See Chapter 7 Part...

Страница 64: ...tting a display mode that is higher than the capability of the monitor v You installed the necessary device drivers for the application 2 Run video diagnostics see Running the diagnostic programs on page 67 v If the server passes the video diagnostics the video is good see Solving undetermined problems on page 110 v Trained service technician only If the server fails the video diagnostics replace ...

Страница 65: ...rts listing TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 on page 201 to determine which components are customer replaceable units CRU and which components are field replaceable units FRU v If an action step is preceded by Trained service technician only that step must be performed only by a Trained service technician v Go to the Lenovo support Web site at http www lenovo com support to ...

Страница 66: ...power cord is connected and that it stays on after the power button is pressed v The server contains the correct type of DIMMs v The DIMMs are correctly seated v A POST beep code did not sound indicating a memory initialization error v The LEDs on the power supply do not indicate a problem v The microprocessor is correctly installed 3 Reseat the following components a DIMMs b power supply cables t...

Страница 67: ...RU and which components are field replaceable units FRU v If an action step is preceded by Trained service technician only that step must be performed only by a Trained service technician v Go to the Lenovo support Web site at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a request for information Symptom Action The number of serial p...

Страница 68: ...en using the software see the information that comes with the software for a description of the messages and suggested solutions to the problem 3 Contact your place of purchase of the software Universal Serial Bus USB port problems v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved v See Chapter 7 Parts listing TS200 Types 6522 652...

Страница 69: ...ch components are customer replaceable units CRU and which components are field replaceable units FRU v If an action step is preceded by Trained service technician only that step must be performed only by a Trained service technician v Go to the Lenovo support Web site at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a request for inf...

Страница 70: ...e server is connected to an ac power source but is not turned on provided that the power supply is operating correctly This feature helps you to isolate the problem when the operating system is shut down Note When you disconnect the power source from the server you lose the ability to view the LEDs because the LEDs are not lit when the power source is removed Before you disconnect the power source...

Страница 71: ...d service technician Component LED Description Action DIMM error LEDs A memory DIMM has failed or is incorrectly installed 1 Remove the DIMM that has the lit error LED 2 Reseat the DIMM 3 Replace the following components one at a time in the order shown restarting the server each time a DIMM b Trained service technician only System board Fan error LEDs A fan has failed is operating too slowly or h...

Страница 72: ...ly Replace the system board PCI slots error LEDs An error has occurred on a PCI bus or on the system board An additional LED is lit next to a failing PCI slot 1 Check the system event log for information about the error 2 If you cannot isolate the failing PCI card through the LEDs and the information in the system event log remove one PCI card at a time and restart the server after each PCI card i...

Страница 73: ... 5 Power LED The following table describes the problems that are indicated by various combinations of the power supply LEDs and the power on LED on the front information panel and suggested actions to correct the detected problems Chapter 4 Diagnostics 65 ...

Страница 74: ...a functioning power source This happens only when a second power supply is providing power to the server Off On Off Faulty power supply Replace the power supply Off On On Faulty power supply Replace the power supply On Off Off Power supply not fully seated faulty system board or faulty power supply 1 Reseat the power supply 2 If the system board error fault LED is not lit replace the power supply ...

Страница 75: ...For more information and to download the utilities go to http www lenovo com thinkserver The DSA diagnostic programs collect information about the following aspects of the system v System configuration v Network interfaces and settings v Hardware inventory including PCI and USB information v Drive health information v SAS SATA RAID and controller configuration v Event logs for ServeRAID controller...

Страница 76: ...the server stops during testing and you cannot continue restart the server and try to run the diagnostic programs again If the problem remains replace the component that was being tested when the server stopped For a list of diagnostic messages see Chapter 4 Diagnostics on page 17 Diagnostic text messages Diagnostic text messages are displayed while the tests are running A diagnostic text message ...

Страница 77: ...tress Test Aborted Internal program error 1 Turn off and restart the system 2 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 3 Run the test again 4 Make sure that the system firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more informat...

Страница 78: ... 4 Make sure that the system firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For the latest level of firmware go to http www lenovo com support and select your system to find available firmware 5 Run the test again 6 Turn off and restart the system if necessary to recover from a hung state 7 Run the test agai...

Страница 79: ...Failed Test failure 1 Turn off and restart the system if necessary to recover from a hung state 2 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 3 Run the test again 4 Make sure that the system firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this compone...

Страница 80: ...st level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web site for more troubleshooting information at http www le...

Страница 81: ... DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web site for mo...

Страница 82: ...est level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web site for more troubleshooting information at http www l...

Страница 83: ...est level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web site for more troubleshooting info...

Страница 84: ...st level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web site for more troubleshooting information at http www le...

Страница 85: ...he DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web site for ...

Страница 86: ...atest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web site for more troubleshooting information at http www...

Страница 87: ...latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web site for more troubleshooting i...

Страница 88: ... latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web site for more troubleshooting information at http w...

Страница 89: ...Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Leno...

Страница 90: ...atest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web site for more troubleshooting in...

Страница 91: ... that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 If the failure remains go to the Lenovo Web si...

Страница 92: ...e in the H8 bus Bus 0 1 Turn off the system and disconnect it from the power source You must disconnect the system from ac power to reset the IMM 2 After 45 seconds reconnect the system to the power source and turn on the system 3 Run the test again 4 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmw...

Страница 93: ...stem from ac power to reset the IMM 2 After 45 seconds reconnect the system to the power source and turn on the system 3 Run the test again 4 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD sect...

Страница 94: ...he system 3 Run the test again 4 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 Disc...

Страница 95: ...r supply bus Bus 3 1 Turn off the system and disconnect it from the power source You must disconnect the system from ac power to reset the IMM 2 After 45 seconds reconnect the system to the power source and turn on the system 3 Run the test again 4 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware...

Страница 96: ... system from ac power to reset the IMM 2 After 45 seconds reconnect the system to the power source and turn on the system 3 Run the test again 4 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD s...

Страница 97: ...re that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 5 Make sure that the IMM firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 Turn off the system and disconnect it from t...

Страница 98: ... For more information see Updating the firmware on page 258 5 Run the test again 6 If the failure remains go to the Lenovo Web site for more troubleshooting information at http www lenovo com support 201 803 xxx Memory Memory Test Aborted Test canceled could not enable the processor cache 1 Turn off and restart the system 2 Run the test again 3 Make sure that the server firmware is at the latest l...

Страница 99: ... For more information see Updating the firmware on page 258 4 Run the test again 5 If the failure remains go to the Lenovo Web site for more troubleshooting information at http www lenovo com support 201 806 xxx Memory Memory Test Aborted Test canceled the memory controller fast scrub operation was not completed 1 Turn off and restart the system 2 Run the test again 3 Make sure that the server fir...

Страница 100: ... Make sure that the server firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 4 Run the test again 5 If the failure remains go to the Lenovo Web site for more troubleshooting information at http www lenovo com support 201 809 xxx Memory Memory Test Abort...

Страница 101: ... the server firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 5 Run the test again 6 If the failure remains go to the Lenovo Web site for more troubleshooting information at http www lenovo com support 201 901 xxx Memory Memory Test Failed Test failure ...

Страница 102: ...server firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 6 Run the test again 7 Replace the failing DIMMs 8 Re enable all memory in the Setup utility see Using the Setup Utility on page 246 9 Run the test again 10 If the failure remains go to the Lenovo...

Страница 103: ...that all memory is enabled by checking the Available System Memory in the Resource Utilization section of the DSA event log If necessary enable all memory in the Setup utility see Using the Setup Utility on page 246 2 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 3 Run the test again 4 Run the standard memory test to validate ...

Страница 104: ... Test v Self Test Messages and actions apply to all three tests Aborted Unable to communicate with the device driver 1 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 2 Run the test again 3 Check the drive cabling at both ends for loose or broken connections or damage to the cable Replace the cable if it is damaged 4 Run the tes...

Страница 105: ...ds 2 Run the test again 3 Insert a new CD DVD into the drive and wait for 15 seconds for the media to be recognized 4 Run the test again 5 Check the drive cabling at both ends for loose or broken connections or damage to the cable Replace the cable if it is damaged 6 Run the test again 7 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com s...

Страница 106: ... seconds 2 Run the test again 3 Check the drive cabling at both ends for loose or broken connections or damage to the cable Replace the cable if it is damaged 4 Run the test again 5 For additional troubleshooting information go to http www lenovo com support 6 Run the test again 7 Replace the CD DVD drive 8 If the failure remains go to the Lenovo Web site for more troubleshooting information at ht...

Страница 107: ...the drive cabling at both ends for loose or broken connections or damage to the cable Replace the cable if it is damaged 4 Run the test again 5 Make sure that the DSA code is at the latest level For the latest level of DSA code go to http www lenovo com support 6 Run the test again 7 For additional troubleshooting information go to http www lenovo com support 8 Run the test again 9 Replace the CD ...

Страница 108: ...ctions at both ends 2 Reseat the all drives 3 Run the test again 4 Make sure that the firmware is at the latest level 5 Run the test again 6 If the failure remains go to the Lenovo Web site for more troubleshooting information at http www lenovo com support 405 901 xxx Intel Ethernet Device Test Control Registers Failed 1 Make sure that the component firmware is at the latest level The installed f...

Страница 109: ...is component For more information see Updating the firmware on page 258 2 Run the test again 3 Replace the component that is causing the error If the error is caused by an adapter replace the adapter Check the PCI Information and Network Settings information in the DSA event log to determine the physical location of the failing component 4 If the failure remains go to the Lenovo Web site for more ...

Страница 110: ...ernal Memory Failed 1 Make sure that the component firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 2 Run the test again 3 Check the interrupt assignments in the PCI Hardware section of the DSA event log If the Ethernet device is sharing interrupts if ...

Страница 111: ...5 904 xxx Intel Ethernet Device Test Interrupt Failed 1 Make sure that the component firmware is at the latest level The installed firmware level is shown in the DSA event log in the Firmware VPD section for this component For more information see Updating the firmware on page 258 2 Run the test again 3 Check the interrupt assignments in the PCI Hardware section of the DSA event log If the Etherne...

Страница 112: ...ction for this component For more information see Updating the firmware on page 258 3 Run the test again 4 Replace the component that is causing the error If the error is caused by an adapter replace the adapter Check the PCI Information and Network Settings information in the DSA event log to determine the physical location of the failing component 5 If the failure remains go to the Lenovo Web si...

Страница 113: ...If the failure remains go to the Lenovo Web site for more troubleshooting information at http www lenovo com support Recovering the server firmware Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code If the server fi...

Страница 114: ... boot recovery jumper back to the primary position pins 1 and 2 14 Reinstall the server cover and then reconnect all the power cables 15 Restart the server See System board switches and jumpers on page 120 for a description of the jumpers and switches In band automated boot recovery method Note Use this method if the System board error LED is lit and there is a log entry or Booting Backup Image is...

Страница 115: ...he default configuration values and automatically goes to F1 Setup To solve the problem complete the following steps 1 Undo any configuration changes that you made recently and restart the server 2 Remove any devices that you added recently and restart the server 3 If the problem remains go to the Setup utility and select Load Default Settings and then click Save to restore the server factory sett...

Страница 116: ...roblems can be difficult to solve For example a short circuit can exist anywhere on any of the power distribution buses Usually a short circuit will cause the power subsystem to shut down because of an overcurrent condition To diagnose a power problem use the following general procedure 1 Turn off the server and disconnect all ac power cords 2 Check for loose cables in the power subsystem Also che...

Страница 117: ...ch the speed and duplex mode of the hub v Check the Ethernet controller LEDs on the rear panel of the server These LEDs indicate whether there is a problem with the connector cable or hub The Ethernet link status LED is lit when the Ethernet controller receives a link pulse from the hub If the LED is off there might be a defective connector or cable or a problem with the hub The Ethernet transmit ...

Страница 118: ... Any external devices v Surge suppressor device on the server v Modem printer mouse and non Lenovo devices v Each adapter v Hard disk drives v Memory modules The minimum configuration requirement is two 1 GB DIMM on the system board The following minimum configuration is required for the server to start v One microprocessor v One 1 GB DIMM on the system board v One power supply v Power cord v Serv...

Страница 119: ...ed Is this the original reported failure v Diagnostic program type and version level v Hardware configuration print screen of the system summary v Server firmware level v Operating system type and version level You can solve some problems by comparing the configuration and software setups between working and nonworking servers When you compare servers to each other for diagnostic purposes consider...

Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...

Страница 121: ... The following illustrations show the controls LEDs and connectors on the front of the server models The following is an illustration of the 3 5 inch SAS SATA hot swap hard disk drive model 1 Hard disk drive activity LED green 7 Hard disk drive activity LED 2 Hard disk drive status LED amber 8 System error LED 3 DVD drive activity LED green 9 USB 2 4 Front information panel 10 USB 1 5 Power on LED...

Страница 122: ... to wake the server from a reduced power state The states of the power on LED are as follows v Off AC power is not present or the power supply or the LED itself has failed v Flashing rapidly 4 times per second The server is turned off and is not ready to be turned on The power control button is disabled This will last approximately 1 to 3 minutes v Flashing slowly once per second The server is tur...

Страница 123: ...is lit it indicates that the drive has failed If an optional RAID controller is installed in the server when this LED is flashing slowly one flash per second it indicates that the drive is being rebuilt When the LED is flashing rapidly three flashes per second it indicates that the controller is identifying the drive Hard disk drive activity LED When this LED is flashing it indicates that the driv...

Страница 124: ...wer supply is supplying adequate dc power to the system During typical operation both the ac and dc power LEDs are lit For any other combination of LEDs see power supply LEDs on page 64 ac power LED Each hot swap power supply has an ac power LED and a dc power LED When the ac power LED is lit it indicates that sufficient power is coming into the power supply through the power cord During typical o...

Страница 125: ... either of these connectors to connect the server to a network When you use the Ethernet 1 connector the network can be shared with the IMM through a single network cable Chapter 5 Locating Server Controls and connectors 117 ...

Страница 126: ... 4 DIMM 4 14 Simple swap HDD backplane signal connector 24 Power 2 connector 5 DIMM 5 15 Wake on LAN connector 25 Virtual media key connector 6 DIMM 6 16 Optical drive connector 26 Power 1 connector 7 Microprocessor 17 Hypervisor flash device connector 27 Power 3 connector 8 Fan 3 connector 18 Slot 5 PCI 32 bit 33 MHz 28 Power 4 connector 9 Fan 2 connector 19 Slot 4 PCI 32 bit 33 MHz 29 Not used 1...

Страница 127: ...ors and the NMI button on the system board Microprocessor Heatsink Orientation DIMMs DIMMs 1 Serial com 1 connector 5 Ethernet connector 2 2 Video connector 6 USB connectors 3 and 4 3 Ethernet connector 1 7 SW1 NMI button 4 USB connectors 1 and 2 Chapter 5 Locating Server Controls and connectors 119 ...

Страница 128: ...t the server responds as if the pins are set to 1 and 2 2 Changing the position of the UEFI boot recovery jumper from pins 1 and 2 to pins 2 and 3 before the server is turned on alters which flash ROM page is loaded Do not change the jumper pin position after the server is turned on This can cause an unpredictable problem Important 1 Before you change any switch settings or move any jumpers turn o...

Страница 129: ...ATA Controller LED 15 DIMM 1 6 error LEDs 8 IMM heart beat LED Table 7 System board LEDs LED Description Error LEDs When one of these LEDs is lit it indicates that the associated component has failed Baseboard management controller heartbeat LED This LED flashes to indicate that the IMM is functioning normally Standby power LED When this LED is lit it indicates that the server is connected to ac p...

Страница 130: ... microprocessor 3 Replace the following components one at a time in the order shown restarting the server each time a Trained service technician only Failing microprocessor b Trained service technician only System board CPU 2 error LED Microprocessor 2 has failed is missing or has been incorrectly installed Note Trained service technician only Make sure that the microprocessors are installed in th...

Страница 131: ...lashes quickly to indicate that the IMM code is loading When the loading is complete the LED stops flashing briefly and then flashes slowly to indicate that the IMM if fully operational and you can press the power control button to start the server If the LED does not begin flashing within 30 seconds of when the server is connected to power do the following 1 Trained service technician only Use th...

Страница 132: ... server is connected to ac power the power control button becomes active the power on LED flashes slowly You can turn on the server by pressing the power control button The server can also be turned on in any of the following ways v If a power failure occurs while the server is turned on the server will restart automatically when power is restored v If your operating system supports the Wake on LA...

Страница 133: ...ore than one power cord To remove all electrical current from the device ensure that all power cords are disconnected from the power source 1 2 The server can be turned off in any of the following ways v You can turn off the server from the operating system if your operating system supports this feature After an orderly shutdown of the operating system the server will be turned off automatically v...

Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...

Страница 135: ...uct for potential unsafe conditions complete the following steps 1 Make sure that the power is off and the power cord is disconnected 2 Make sure that the exterior cover is not damaged loose or broken and observe any sharp edges 3 Check the power cord v Make sure that the third wire ground connector is in good condition Use a meter to measure third wire ground continuity for 0 1 ohm or less betwee...

Страница 136: ... complete circuit that could cause an electrical shock When you use a tester set the controls correctly and use the approved probe leads and accessories for that tester Stand on a suitable rubber mat to insulate you from grounds such as metal floor strips and equipment frames v Use extreme care when you measure high voltages v To ensure proper grounding of components such as power supplies pumps b...

Страница 137: ...rs can handle and damage it v While the device is still in its static protective package touch it to an unpainted metal part on the outside of the server for at least 2 seconds This drains static electricity from the package and from your body v Remove the device from its package and install it directly into the server without setting down the device If it is necessary to set down the device put i...

Страница 138: ...ptional hardware make sure that the server is working correctly Start the server and make sure that the operating system starts if an operating system is installed If the server is not working correctly see the Hardware Maintenance Manual for diagnostic information To remove the server side cover complete the following steps Attention Operating the server for more than 30 minutes with the side cov...

Страница 139: ...l internal cables are correctly routed 2 If you removed the upper and lower bezels reinstall them before you replace the side cover see Installing the upper bezel on page 134 and Installing the lower bezel on page 133 Important The cover lock must be in the unlocked opened position before you install the side cover 3 Position the lip on the bottom edge of the side cover on the ledge on the bottom ...

Страница 140: ...teps 1 Read the safety information that begins on page 1 2 Unlock the side cover 3 Remove the side cover see Removing the side cover on page 130 4 Press the round blue release button on the right side of the lower bezel and tilt the lower bezel forward to disengage it from the chassis 5 Lift the lower bezel to disengage the two bottom tabs from the chassis Set the lower bezel aside 132 ThinkServer...

Страница 141: ...l see Installing the lower bezel and Installing the upper bezel on page 134 Installing the lower bezel To install the lower bezel complete the following steps 1 Insert the two bottom tabs on the lower bezel into the corresponding holes in the front of the chassis 2 Rotate the top of the lower bezel up to the chassis then press the blue release tab on the right side of the lower bezel and completel...

Страница 142: ...er information that you must consider when you install DIMMs see System board internal connectors on page 118 for the location of the DIMM connectors v The server supports industry standard 1066 or 1333 MHz PC3 10600R 999 single rank or dual rank double data rate 3 DDR3 registered synchronous dynamic random access memory SDRAM dual inline memory modules DIMMs with error correcting code ECC See htt...

Страница 143: ...uffered DIMM UDIMM with ECC x72 bit module data bus R Registered DIMM RDIMM U Unbuffered DIMM with no ECC x64 bit primary data bus aa is the CAS latency in clocks at maximum operating frequency bb is the JEDEC SPD Revision Encoding and Additions level cc is the reference design file for the design of the DIMM d is the revision number of the reference design of the DIMM Note To determine the type o...

Страница 144: ...4 DIMMs connector 5 DIMMs connector 6 populated empty empty empty empty empty populated empty empty populated empty empty populated populated empty populated populated empty Registered DIMMs RDIMMs The following notes provide information that you must consider when you install RDIMMs see System board internal connectors on page 118 for the location of the DIMM connectors v The memory channels run ...

Страница 145: ...pulation rule for dual channel symmetric mode DIMMs connector 1 DIMMs connector 2 DIMMs connector 3 DIMMs connector 4 DIMMs connector 5 DIMMs connector 6 populated empty empty empty empty empty populated empty empty populated empty empty populated populated empty populated populated empty populated populated populated populated populated populated Removing a memory module To remove a dual inline m...

Страница 146: ...tial problem always use an electrostatic discharge wrist strap or other grounding system when working inside the server with the power on To install a DIMM complete the following steps 1 Read the safety information that begins on page 1 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary 3 Remove the cover see Removing the side cover on ...

Страница 147: ... see System board internal connectors on page 118 for the location of the DIMM connectors 8 Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously The retaining clips snap into the locked position when the DIMM is firmly seated in the connector Note If there is a gap between the DIMM and the retaining clips the DIMM has not been correctl...

Страница 148: ...drives that the server supports and other important information The following figure shows the locations of the drive bays in the server 1 Bay 1 2 Bay 2 3 Bay 3 4 Bay 4 5 Bay 5 6 Bay 6 7 Bay 7 140 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...

Страница 149: ...xamples of removable media drives You can install removable media drives in bays 1 2 and 3 only v The SATA removable media drives that you install in bay 1 connects to the SATA 4 connector on the system board and the drive in bay 2 connects to the SATA 5 connector on the system board v To install a 3 5 inch drive in a 5 25 inch bay you must use the 5 25 inch conversion kit v The electromagnetic in...

Страница 150: ...ip to use when you install the replacement drive 8 If you are instructed to return the drive follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing a DVD drive To install a DVD drive complete the following steps 1 If you are replacing a removed drive with a new drive make sure that v You have all the cables and other equipment that is spe...

Страница 151: ... the beam Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil A Laser de Classe 1 2 Touch the static protective package that contains the new DVD drive to any unpainted metal surface on the server then remove the DVD drive from the package and place it on a static protective surface 3 Follow the instructions that come with the drive to set jumpers or switches if there a...

Страница 152: ...server and peripheral devices and disconnect the power cords and all external cables 3 Unlock and remove the side cover see Installing the side cover on page 131 4 Remove the lower bezel see Installing the lower bezel on page 133 5 Remove the upper bezel see Installing the upper bezel on page 134 6 Disconnect the power and signal cables from the drive that is to be removed 7 Press and hold the blu...

Страница 153: ... removed the drive retainer clip on the side of the old drive and have it available for installation on the new drive 2 Read the safety information that begins on page 1 3 Turn off the server and peripheral devices and disconnect the power cords and all external cables 4 Unlock and remove the side cover see Installing the side cover on page 131 5 Remove the lower bezel see Installing the lower bez...

Страница 154: ...l cables for internal drives on page 151 13 Route the signal cable so that it does not block the airflow to the rear of the drives or over the microprocessor and dual inline memory modules DIMMs 14 Connect the power cable to the rear of the drive The connectors are keyed and can be inserted only one way 15 Go to Completing the FRU replacement on page 190 Removing a hot swap hard disk drive This pr...

Страница 155: ... are instructed to return the drive assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you IDs for hot swap hard disk drives On some models the hot swap drive backplane controls the IDs of the internal hot swap drive bays The following table lists the IDs of the hard disk drives and backplane that are connected to one channel in the hot swa...

Страница 156: ...ng steps 1 Touch the static protective package that contains the drive to any unpainted metal surface on the server then remove the drive from the package and place it on a static protective surface 2 Make sure that the drive tray handle is in the open position 3 Align the drive assembly with the guide rails in the bay then carefully slide the drive assembly 1 into the drive bay until the drive st...

Страница 157: ...ServeRAID controller you might have to reconfigure the disk arrays after you replace hard disk drives See the ServeRAID documentation for additional information about RAID operation 6 Go to Completing the FRU replacement on page 190 Chapter 6 Replacing FRUs 149 ...

Страница 158: ...nformation that begins on page 1 2 Turn off the server and all attached devices then disconnect all power cords and external cables 3 Remove the lower bezel see Removing the two piece bezel on page 131 4 Pull the loops of the drive assembly that is to be removed toward each other then pull the assembly out of the bay 5 If you are instructed to return the drive assembly follow all packaging instruc...

Страница 159: ...letely seated 4 Go to Completing the FRU replacement on page 190 Power and signal cables for internal drives The server uses cables to connect SATA attached simple swap SATA hot swap SATA and hot swap SAS devices to the power supply and to the system board See System board internal connectors on page 118 for the location of system board connectors Review the following information before connecting...

Страница 160: ...ot required for these drives For more information about the requirements for SAS SATA cables and connecting SAS SATA devices see the documentation that comes with these devices See http www lenovo com thinkserver and click the Options tab for a list of supported options Replacing an adapter Use the following procedures to replace an adapter Removing an adapter To remove an adapter complete the fol...

Страница 161: ...ocate the documentation that comes with the adapter and follow those instructions in addition to the instructions in this section If you must change the switch setting or jumper settings on the adapter follow the instructions that come with the adapter v Read the documentation that comes with your operating system v The server comes with the following adapter connectors or slots Slot 1 PCIe2 x8 x8...

Страница 162: ...ich might result in the loss of data To avoid this potential problem always use an electrostatic discharge wrist strap or other grounding system when you work inside the server with the power on To install an adapter complete the following steps 1 Read the safety information that begins on page 1 2 Turn off the server and peripheral devices and disconnect all external cables and power cords then r...

Страница 163: ... 6 Front adapter retention bracket 7 Touch the static protective package that contains the adapter to any unpainted metal surface on the server Then remove the adapter from the static protective package Avoid touching the components and gold edge connectors on the adapter Chapter 6 Replacing FRUs 155 ...

Страница 164: ...server are large or have heavy cables attached to them you can remove the rear adapter retention bracket and secure all of the adapters with expansion slot screws 14 Go to Completing the FRU replacement on page 190 Replacing the ServeRAID BR10il v2 SAS SATA controller Use the following procedures to replace the ServeRAID BR10il v2 SAS SATA controller Removing a ServeRAID BR10 il controller To remo...

Страница 165: ... into the hole on the system board 8 If you are instructed to return the SAS SATA controller follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing a ServeRAID BR10 il controller To install the SAS SATA RAID controller complete the following steps 1 Touch the static protective package that contains the SAS SATA controller to any unpainted...

Страница 166: ...RAID MR10i adapter is supported on hot swap server models only The IBM ServeRAID MR10i SAS SATA adapter enables integrated RAID levels 0 1 5 6 and 10 support capability on hot swap hard disk drives For configuration information see the documentation on the ServeRAID CD that comes with the adapter Important To ensure that any of your ServeRAID 10i 10is or 10M adapters function properly on UEFI base...

Страница 167: ... to the new ServeRAID adapter 7 Press the ServeRAID MR10i adapter firmly into the connector on the system board 8 Reconnect the cables to the new ServeRAID MR10i adapter Removing an optional ServeRAID MR10is VAULT SAS SATA controller To remove a ServeRAID MR10is SAS SATA adapter complete the following steps 1 Read the safety information beginning on page 1 2 Turn off the server and peripheral devi...

Страница 168: ...FI based servers make sure that the adapter firmware level is updated and the supporting drivers are installed Attention Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code To install the PCIe adapter card complete the followi...

Страница 169: ...aining tab on top of the drive cage while you rotate the drive cage into the chassis until it is in the closed position 13 Reinstall the hard disk drives Note Before you continue check all internal power cables to make sure that they are connected to the system board and other optional devices 14 Go to Completing the FRU replacement on page 190 Replacing a USB embedded hypervisor flash device Use ...

Страница 170: ... steps 1 Read the safety information that begins on page 1 2 Turn off the server and peripheral devices and disconnect all power cords then remove the side cover see Removing the side cover on page 130 3 Grasp the virtual media key and gently slide it up and off of the mounting tab 1 Mounting bracket feet 2 Mounting tab 3 Virtual media key connector 4 Virtual media key front 4 If you are instructe...

Страница 171: ...board Press the virtual media key down into the connector until it is firmly seated on the system board 1 Mounting bracket rear 2 Mounting tab 3 Virtual media key connector 4 Virtual media key front 4 Go to Completing the FRU replacement on page 190 Replacing the rear system fan Attention v Replace a failed fan within 48 hours v To ensure proper cooling and airflow do not operate the server for mo...

Страница 172: ... the fan up and out of the chassis 7 If you are instructed to return the fan follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing the rear system fan To install the rear system fan complete the following steps 1 The replacement fan comes with the rubber grommets installed 1 however they might have come out during shipment If any of the ...

Страница 173: ... disk drive fan assembly To remove the hard disk drive fan assembly complete the following steps 1 Read the safety information that begins on page 1 2 Turn off the server and all attached devices then disconnect all power cords and external cables 3 Unlock and remove the side cover see Removing the side cover on page 130 4 Rotate the rear adapter retention bracket to the open unlocked position 5 D...

Страница 174: ... on the hard disk drive fan assembly release tabs then rotate the assembly away from the drive cage slightly 1 Release tabs 2 Hard disk drive fan assembly 3 Slot 166 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...

Страница 175: ...fully close the hard disk drive fan assembly 1 Release tabs 2 Hard disk drive fan assembly 3 Slot 2 Route the hard disk drive signal and power cables through the slots on the edge of the hard disk drive fan assembly Make sure that the cables will not be pinched between the hard disk drive assembly and the hard disk drive backplane when the assembly is installed 3 Rotate the hard disk drive fan ass...

Страница 176: ...the server and all attached devices then disconnect all power cords and external cables 3 Unlock and remove the side cover see Removing the side cover on page 130 4 Remove the lower bezel see Removing the two piece bezel on page 131 5 Remove the simple swap hard disk drives that are installed in the hard disk drive cage see Removing a simple swap hard disk drive on page 150 6 Remove the hard disk ...

Страница 177: ...llow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing the simple swap backplate This procedure applies only to server models with the simple swap SATA backplate installed on the back of the hard disk drive cage To install the simple swap backplate complete the following steps 1 Position the bottom edge of the simple swap backplate on the l...

Страница 178: ...hard disk drive cage see Replacing the hard disk drive fan assembly on page 165 7 Install the simple swap hard disk drives that you removed from the hard disk drive cage see Installing a simple swap hard disk drive on page 151 8 Go to Completing the FRU replacement on page 190 Replacing the SAS SATA hard disk drive backplane Use these procedures to replace he SAS SATA hard disk drive backplane The...

Страница 179: ...g tab on top of the cage locks into place 9 Remove the two screws that secure the SAS SATA hard disk drive backplane to the drive cage 1 Locating pins 2 Retaining tab 3 Retaining latch 4 Drive cage release tab 10 Tilt the top of the hard disk drive backplane away from the drive cage until it is clear of the locating pins 11 Lift the SAS SATA hard disk drive backplane out of the lower lip on the dr...

Страница 180: ...mbly onto the hard disk drive cage see Installing the hard disk drive fan assembly on page 167 7 Install the hot swap hard disk drives that you removed from the hard disk drive cage see Installing a hot swap hard disk drive on page 148 8 Go to Completing the FRU replacement on page 190 Replacing the front panel assembly Use the following procedures to replace the front panel assembly Removing the ...

Страница 181: ...re instructed to return the front panel assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing the front panel assembly To install the front panel assembly complete the following steps 1 Position the front end of the front panel assembly in the channel above drive bay 1 on the left side of the chassis 2 Push the front panel assem...

Страница 182: ... the location of the front USB connector 6 Press down and hold the release tab on the top of the front USB housing then tilt the top of the housing away from the chassis and lift the housing out of the opening in the chassis 7 Squeeze the spring clips 1 on the sides of the front USB connector assembly and pull the assembly out of the back of the housing 8 Carefully pull the front USB cable out of ...

Страница 183: ...bracket complete the following steps 1 Turn off the server and all attached devices then disconnect all power cords and external cables 2 Unlock and remove the side cover see Removing the side cover on page 130 3 Remove all adapters if necessary and place the adapters on static protective surface Note You might find it helpful to note where each adapter is installed before you remove the adapters ...

Страница 184: ... Open the front and rear adapter retention brackets 5 Remove all adapters if necessary and place them on a static protective surface Note You might find it helpful to note where each adapter is installed before you remove the adapters 6 Grasp one side of the bracket at a hinge point and pull outward while you rotate the bracket slightly toward the rear of the server until the hinge pin on the brac...

Страница 185: ... 180 Note It might be helpful to lay the server on its side for the remainder of this procedure 5 Disconnect the cables from the power supply cage to the system board and all internal components 6 Remove the four black screws that secure the power supply cage to the chassis then slide the cage toward the front of the server to disengage the retaining clips 1 from the top of the chassis and lift th...

Страница 186: ...s When you remove or install a hot swap power supply observe the following precautions Statement 8 CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of thes...

Страница 187: ...rver models that have hot swap power supplies To install a hot swap power supply complete the following steps 1 Place the power supply into the bay guides 2 Using the handle push the power supply toward the front of the chassis until it locks into place 3 Connect one end of the power cord into the connector on the back of the power supply and connect the other end of the power cord into a properly...

Страница 188: ...safety information that begins on page 1 2 Turn off the server and all attached devices then disconnect all power cords and external cables 3 Unlock and remove the side cover see Removing the side cover on page 130 Note It might be helpful to lay the server on its side for the remainder of this procedure 4 Disconnect the cables from the power supply to the system board and all internal components ...

Страница 189: ...ng a non hot swap power supply This procedure applies only to server models that have a non hot swap power supply To install a non hot swap power supply complete the following steps 1 Position the power supply in the chassis so that the screw holes in the power supply are aligned with the corresponding holes in the rear of the chassis Chapter 6 Replacing FRUs 181 ...

Страница 190: ... 3 Turn the server on its side so that it is lying flat with the cover facing up 4 Unlock and remove the side cover see Removing the side cover on page 130 5 Remove the lower bezel see Removing the two piece bezel on page 131 6 Remove the hard disk drives 7 Press and hold the drive cage release tab then rotate the drive cage out of the chassis until the retaining tab on top of the cage locks into ...

Страница 191: ...croprocessor retention latch by pressing down on the end moving it to the side and slowly releasing it to the open up position 11 Open the microprocessor bracket frame by lifting up the tab on the top edge 12 Carefully lift the microprocessor straight up and out of the socket and place it on a static protective surface 13 If you are instructed to return the microprocessor and fan sink follow all p...

Страница 192: ...roprocessor has two notches that are keyed to two tabs on the sides of the socket v A triangle shaped indicator on one corner of the microprocessor points to a 45 degree angle on one corner of the socket v Do not use excessive force when you press the microprocessor into the socket 5 Close the microprocessor bracket frame then close the microprocessor retention latch and lock it securely in place ...

Страница 193: ...grease The thermal grease must be replaced whenever the fan sink has been removed from the top of the microprocessor and is going to be reused or when debris is found in the grease When you are installing the fan sink on the same microprocessor that is was removed from make sure that v The thermal grease on the fan sink and microprocessor is not contaminated v Additional thermal grease is not adde...

Страница 194: ...t it is lying flat with the cover facing up 4 Unlock and remove the side cover see Removing the side cover on page 130 5 Note where each cable is connected then disconnect all cables from the system board 6 Press and hold the drive cage release tab then rotate the drive cage out of the chassis until the retaining tab on top of the cage locks into place 7 Remove any of the following components in a...

Страница 195: ...aterials for shipping that are supplied to you Installing the system board To install the system board complete the following steps 1 Touch the static protective package that contains the system board to any unpainted metal surface on the server Then remove the system board from the package 2 Install the fan connector covers onto fan connectors 1 3 and 5 on the system board 3 Install the microproc...

Страница 196: ...v Adapters see Installing an adapter on page 153 7 Press and hold the retaining tab on top of the cage then rotate the drive cage into the chassis until it locks into place 8 Reconnect any cables to the system board that you disconnected during removal 9 When a new system board is installed you must update the UUID and the DMI SMBIOS data See Updating the Universal Unique Identifier UUID on page 1...

Страница 197: ...ce the battery with a lithium battery of the same type from the same manufacturer v After you replace the battery you must reconfigure the server and reset the system date and time v To avoid possible danger read and follow the following safety statement Statement 2 CAUTION When replacing the lithium battery use only Part Number 33F8354 or an equivalent type battery recommended by the manufacturer...

Страница 198: ...246 6 Go to Completing the FRU replacement Completing the FRU replacement To complete the FRU replacement you must v If removed reinstall the two piece bezel see Reinstalling the two piece bezel v If removed reinstall the side cover see Reinstalling the side cover on page 193 v Connect all the cables see Connecting the cables on page 194 v For some devices run the Setup utility see Using the Setup...

Страница 199: ...Chapter 6 Replacing FRUs 191 ...

Страница 200: ...t of the chassis b Rotate the top of the lower bezel up to the chassis then press the blue release tab on the right side of the lower bezel and completely close the lower bezel until it locks securely into place 192 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...

Страница 201: ...erver Also make sure that all internal cables are correctly routed Note The cover release latch must be in the unlocked opened position before you install the side cover 2 Position the lip on the bottom edge of the side cover on the ledge on the bottom of the chassis then rotate the cover up to the chassis and then press down on the cover release latch and push the cover completely closed until it...

Страница 202: ...r on page 245 Some optional devices have device drivers that you must install For information about installing device drivers see the documentation that comes with each device The server comes with at least one microprocessor If more than one microprocessor is installed the server can operate as a symmetric multiprocessing SMP server You might have to upgrade the operating system to support SMP Fo...

Страница 203: ...the same directory In addition to the application executable asu or asu64 the following files are required v For Windows based operating systems ibm_rndis_server_os inf device cat v For Linux based operating systems cdc_interface sh 4 After you install ASU use the following command syntax to set the UUID asu set SYSTEM_PROD_DATA SysInfoUUID uuid_value access_method Where uuid_value Up to 16 byte h...

Страница 204: ...ternal_ip address are required parameters host imm_external_ip user imm_user_id password imm_password Where imm_external_ip The external IMM LAN IP address There is no default value This parameter is required imm_user_id The IMM account 1 of 12 accounts The default value is USERID imm_password The IMM account password 1 of 12 accounts The default value is PASSW0RD with a zero 0 not an O The follow...

Страница 205: ...sset_tag access_method Where m t_model The server machine type and model number Type mtm xxxxyy where xxxx is the machine type and yyy is the server model number s n The serial number on the server Type sn zzzzzzz where zzzzzzz is the serial number asset_method The server asset tag number Type asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the asset tag number a...

Страница 206: ...he ASU Users Guide The following commands are examples of using the userid and password default values and not using the default values Examples that do not use the userid and password default values asu set SYSTEM_PROD_DATA SYsInfoProdName m t_model asu set SYSTEM_PROD_DATA SYsInfoSerialNum s n asu set SYSTEM_PROD_DATA SYsEncloseAssetTag asset_tag v Remote LAN access type the command Note When us...

Страница 207: ...rid and password default values asu set SYSTEM_PROD_DATA SysInfoProdName m t_model host imm_ip asu set SYSTEM_PROD_DATA SysInfoSerialNum s n host imm_ip asu set SYSTEM_PROD_DATA SysEncloseAssetTag asset_tag host imm_ip 5 Restart the server Chapter 6 Replacing FRUs 199 ...

Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...

Страница 209: ...6525 6526 6528 6529 and 6530 servers To check for an updated parts listing on the Web complete the following steps 1 Go to http www lenovo com support 2 Enter your product number machine type and model number or select Servers and Storage from the Select your product list 3 From Family list select ThinkServer TS200 and click Continue Lenovo 2009 Portions IBM Corp 2007 2009 201 ...

Страница 210: ...ranty and getting service and assistance see the Warranty and Support Information document 11 5 18 21 6 16 17 19 14 8 10 7 9 3 2 15 13 12 1 4 20 Table 15 Parts listing Type 6522 Index Description CRU part number Self service CRU part number Optional service FRU part number 1 Chassis assembly models CTO All Models 49Y8457 2 Operator Information Panel Assembly models CTO All Models 49Y8456 3 Front U...

Страница 211: ... CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 45J9648 8 Hard disk drive IBM 450GB 15K SAS 3 5 HS HDD models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U2108 8 Hard disk drive IBM Server 1TB 7200 SATA 3 5 Simple Swap HDD models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U2916 8 Hard disk drive 73GB 15K 3 5 Hot Swap SAS HDD models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U2088 8 Hard disk ...

Страница 212: ...Retention bracket rear adapter models CTO All Models 49Y8450 19 Power supply 401w PSU Fixed models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46M6678 19 Power supply 430w PSU H S models CTO 46M6679 20 Memory 1GB DDR3 1333 1Rx8 LP RDIMM models CTO 46U1991 20 Memory 1GB 1x1GB Single Rankx8 PC3 10600 CL9 ECC DDR3 1333MHz LP UDIMM models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U2906 20 Memory 2...

Страница 213: ... SAS signal 3 5 inch hot swap hard disk drive models CTO All Models 46M6498 Cable SATA signal 3 5 inch simple swap hard disk drive models CTO All Models 49Y8444 Cable 1Mx4 SAS Mini models CTO All Models 39R6530 Cable 3Mx4 SAS Mini models CTO All Models 39R6532 Cable optical disk drive tape drive models CTO All Models 25R5635 EMC shield models CTO All Models 49Y8455 EMC shield kit optical disk driv...

Страница 214: ...l Models 90Y1174 WS 2008 SBS SP2 STD 64bit NL models CTO All Models 90Y1175 WS 2008 SBS SP2 STD 64bit FR models CTO All Models 90Y1176 WS 2008 SBS SP2 STD 64bit GR models CTO All Models 90Y1177 WS 2008 SBS SP2 STD 64bit IT models CTO All Models 90Y1178 WS 2008 SBS SP2 STD 64bit JP models CTO All Models 90Y1179 WS 2008 SBS SP2 STD 64bit SP models CTO All Models 90Y1180 WS 2008 SBS SP2 STD 64bit TR ...

Страница 215: ...1M 11A 11J 46U2948 8 Hard disk drive 250GB 7200 RPM 3 5 Simple Swap SATA II models CTO 11G 11M 11A 11J 45J9634 8 Hard disk drive 500GB 7200 RPM 3 5 Simple Swap SATA II models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U1024 8 Hard disk drive 250GB 7200 RPM 3 5 Hot Swap SATA II models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 45J9642 8 Hard disk drive 500GB 7200 RPM 3 5 Hot Swap SATA II models...

Страница 216: ...late simple swap models 25R8842 12 Hard disk drive fan assembly for 3 5 inch drive cage models 39Y9860 13 System board assembly models CTO All Models 69Y1013 14 ServeRAID BR10il SAS SATA controller models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 49Y4737 15 Microprocessor Celeron G1101 2 26GHz 1066MHz 2MB 2C models CTO 49Y4645 15 Microprocessor Xeon X3460 2 8GHz 1333MHz 8MB 4C models CTO 49Y4646...

Страница 217: ...TO All Models 33F8354 EMC SAS SATA Backplate models CTO All Models 25R8784 ServeRAID MR10i adapter models CTO 43W4297 ServeRAID MR10is VAULT adapter models CTO 44E8696 IBM 3Gb SAS HBA Controller v2 models CTO 44E8701 ServeRAID M5015 SAS SATA Controller models CTO 46M0851 ServeRAID M5025 SAS SATA Controller models CTO 46M0854 ServeRAID M1015 SAS SATA Controller models CTO 46M0862 ServeRAID MR10i Li...

Страница 218: ...els 39M4375 Kit Retainer for optical and diskette drives models CTO All Models 39R9369 Power supply unit adapter models CTO All Models 42C7509 Miscellaneous parts kit models CTO All Models 39Y9773 Power supply cage 430 watt models CTO All Models 49Y8459 Retention module for fan sink models CTO All Models 49Y8458 Side top cover models CTO All Models 49Y8446 System service label models CTO All Model...

Страница 219: ...Y1189 WS 2008 R2 STD 64bit NL models CTO All Models 90Y1190 WS 2008 R2 ENT 64bit US models CTO All Models 90Y1191 WS 2008 R2 ENT 64bit NL models CTO All Models 90Y1192 WS 2008 R2 ENT 64bit FR models CTO All Models 90Y1193 WS 2008 R2 ENT 64bit GR models CTO All Models 90Y1194 WS 2008 R2 ENT 64bit IT models CTO All Models 90Y1195 WS 2008 R2 ENT 64bit JP models CTO All Models 90Y1196 WS 2008 R2 ENT 6...

Страница 220: ...els CTO 46U2108 8 Hard disk drive IBM Server 1TB 7200 SATA 3 5 Simple Swap HDD models CTO 46U2916 8 Hard disk drive 73GB 15K 3 5 Hot Swap SAS HDD models CTO 46U2088 8 Hard disk drive ThinkServer 300GB 6Gbps 15K 3 5 Hot Swap SAS drive models CTO All Models 46U3014 8 Hard disk drive ThinkServer 450GB 6Gbps 15K 3 5 Hot Swap SAS drive models CTO All Models 46U3015 8 Hard disk drive ThinkServer 600GB 6...

Страница 221: ...M6678 19 Power supply 430w PSU H S models CTO 46M6679 20 Memory 1GB DDR3 1333 1Rx8 LP RDIMM models CTO 46U1991 20 Memory 1GB 1x1GB Single Rankx8 PC3 10600 CL9 ECC DDR3 1333MHz LP UDIMM models CTO 46U2906 20 Memory 2GB DDR3 1333 2Rx8 LP UDIMM models CTO 46U2907 20 Memory 2GB DDR3 1333 2Rx8 LP RDIMM models CTO 46U1992 20 Memory 4GB 1x4GB Quad Rankx8 PC3 8500 CL7 ECC DDR3 1066MHz LP RDIMM models CTO ...

Страница 222: ... 1Mx4 SAS Mini models CTO All Models 39R6530 Cable 3Mx4 SAS Mini models CTO All Models 39R6532 Cable optical disk drive tape drive models CTO All Models 25R5635 EMC shield models CTO All Models 49Y8455 EMC shield kit optical disk drive tape drive models CTO All Models 13N2997 Feet chassis models CTO All Models 13N2985 Hard disk drive carrier 3 5 inch simple swap models CTO All Models 42C7495 Hard ...

Страница 223: ...STD 64bit GR models CTO All Models 90Y1177 WS 2008 SBS SP2 STD 64bit IT models CTO All Models 90Y1178 WS 2008 SBS SP2 STD 64bit JP models CTO All Models 90Y1179 WS 2008 SBS SP2 STD 64bit SP models CTO All Models 90Y1180 WS 2008 SBS SP2 STD 64bit TR models CTO All Models 90Y1181 WS 2008 SBS SP2 PREM 64bit US models CTO All Models 90Y1182 WS 2008 R2 STD 64bit US models CTO All Models 90Y1183 WS 2008...

Страница 224: ...12A 12J 13G 13M 13A 13J 14U 14F 14S 14L 14D 14Y 14G 14M 14A 14J 46U2948 8 Hard disk drive 250GB 7200 RPM 3 5 Simple Swap SATA II models CTO 11G 11M 11A 11J 45J9634 8 Hard disk drive 500GB 7200 RPM 3 5 Simple Swap SATA II models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U1024 8 Hard disk drive 250GB 7200 RPM 3 5 Hot Swap SATA II models CTO 12U 12F 12S 12L 12D 12Y 12G 12M 12A 12J 13G 13M 13A 13J...

Страница 225: ...U3014 8 Hard disk drive ThinkServer 450GB 6Gbps 15K 3 5 Hot Swap SAS drive models CTO All Models 46U3015 8 Hard disk drive ThinkServer 600GB 6Gbps 15K 3 5 Hot Swap SAS drive models CTO All Models 46U3016 9 Retention bracket front adapter models CTO All Models 13N2993 10 Hard disk drive cage 3 5 inch drives models CTO All Models 49Y8451 11 SAS SATA hard disk drive backplane for 3 5 inch drive cage ...

Страница 226: ...2906 20 Memory 2GB DDR3 1333 2Rx8 LP UDIMM models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U2907 20 Memory 2GB DDR3 1333 2Rx8 LP RDIMM models CTO 14U 14F 14S 14L 14D 14Y 14G 14M 14A 14J 46U1992 20 Memory 4GB 1x4GB Quad Rankx8 PC3 8500 CL7 ECC DDR3 1066MHz LP RDIMM models 12U 12F 12S 12L 12D 12Y 12G 12M 12A 12J 13G 13M 13A 13J 46U2941 20 Memory 8GB 1x8GB Quad Rankx8 PC3 8500 CL7 ECC DDR3 1066M...

Страница 227: ...44 Cable 1Mx4 SAS Mini models CTO All Models 39R6530 Cable 3Mx4 SAS Mini models CTO All Models 39R6532 Cable optical disk drive tape drive models CTO All Models 25R5635 EMC shield models CTO All Models 49Y8455 EMC shield kit optical disk drive tape drive models CTO All Models 13N2997 Feet chassis models CTO All Models 13N2985 Hard disk drive carrier 3 5 inch simple swap models CTO All Models 42C74...

Страница 228: ...t GR models CTO All Models 90Y1177 WS 2008 SBS SP2 STD 64bit IT models CTO All Models 90Y1178 WS 2008 SBS SP2 STD 64bit JP models CTO All Models 90Y1179 WS 2008 SBS SP2 STD 64bit SP models CTO All Models 90Y1180 WS 2008 SBS SP2 STD 64bit TR models CTO All Models 90Y1181 WS 2008 SBS SP2 PREM 64bit US models CTO All Models 90Y1182 WS 2008 R2 STD 64bit US models CTO All Models 90Y1183 WS 2008 R2 STD ...

Страница 229: ...M 3 5 Simple Swap SATA II models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U1024 8 Hard disk drive 250GB 7200 RPM 3 5 Hot Swap SATA II models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 45J9642 8 Hard disk drive 500GB 7200 RPM 3 5 Hot Swap SATA II models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 45J9644 8 Hard disk drive 146GB 15K 3 5 Hot Swap SAS models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 1...

Страница 230: ... assembly models CTO All Models 69Y1013 14 ServeRAID BR10il SAS SATA controller models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 49Y4737 15 Microprocessor Celeron G1101 2 26GHz 1066MHz 2MB 2C models CTO 49Y4645 15 Microprocessor Xeon X3460 2 8GHz 1333MHz 8MB 4C models CTO 49Y4646 15 Microprocessor models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 49Y4647 15 Microprocessor Xeon X3440 2 53GHz 133...

Страница 231: ... adapter models CTO 44E8696 IBM 3Gb SAS HBA Controller v2 models CTO 44E8701 ServeRAID M5015 SAS SATA Controller models CTO 46M0851 ServeRAID M5025 SAS SATA Controller models CTO 46M0854 ServeRAID M1015 SAS SATA Controller models CTO 46M0862 ServeRAID MR10i Li Ion Battery models CTO 43W4301 ServeRAID MR10M SAS SATA Controller with Remote Battery Kit models CTO 43W4341 ServeRAID M1015 RAID 5 Upgrad...

Страница 232: ...dels CTO All Models 39Y9773 Power supply cage 430 watt models CTO All Models 49Y8459 Retention module for fan sink models CTO All Models 49Y8458 Side top cover models CTO All Models 49Y8446 System service label models CTO All Models 49Y8452 USB hypervisor key models Virtual media key models 6526 Software FRU FRU EasyManage models CTO All Models 69Y9937 Documentation DVD models CTO All Models 90Y11...

Страница 233: ...models CTO All Models 90Y1192 WS 2008 R2 ENT 64bit FR models CTO All Models 90Y1193 WS 2008 R2 ENT 64bit GR models CTO All Models 90Y1194 WS 2008 R2 ENT 64bit IT models CTO All Models 90Y1195 WS 2008 R2 ENT 64bit JP models CTO All Models 90Y1196 WS 2008 R2 ENT 64bit SP models CTO All Models 90Y1197 WS 2008 R2 ENT 64bit TR models CTO All Models 90Y1198 ROK WS2008 FOUND 64bit MUI EN JP models CTO Al...

Страница 234: ... 11F 11S 11L 11D 11Y 11G 11M 11A 11J 45J9648 8 Hard disk drive IBM 450GB 15K SAS 3 5 HS HDD models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U2108 8 Hard disk drive IBM Server 1TB 7200 SATA 3 5 Simple Swap HDD models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U2916 8 Hard disk drive 73GB 15K 3 5 Hot Swap SAS HDD models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U2088 8 Hard disk drive Th...

Страница 235: ...n bracket rear adapter models CTO All Models 49Y8450 19 Power supply 401w PSU Fixed models CTO 46M6678 19 Power supply 430w PSU H S models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46M6679 20 Memory 1GB DDR3 1333 1Rx8 LP RDIMM models CTO 46U1991 20 Memory 1GB 1x1GB Single Rankx8 PC3 10600 CL9 ECC DDR3 1333MHz LP UDIMM models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 46U2906 20 Memory 2GB DDR3 ...

Страница 236: ...d disk drive models CTO All Models 49Y8448 Cable SAS signal 3 5 inch hot swap hard disk drive models CTO All Models 46M6498 Cable SATA signal 3 5 inch simple swap hard disk drive models CTO All Models 49Y8444 Cable 1Mx4 SAS Mini models CTO All Models 39R6530 Cable 3Mx4 SAS Mini models CTO All Models 39R6532 Cable optical disk drive tape drive models CTO All Models 25R5635 EMC shield models CTO All...

Страница 237: ...O All Models 90Y1173 WS 2008 SBS SP2 STD 64bit US models CTO All Models 90Y1174 WS 2008 SBS SP2 STD 64bit NL models CTO All Models 90Y1175 WS 2008 SBS SP2 STD 64bit FR models CTO All Models 90Y1176 WS 2008 SBS SP2 STD 64bit GR models CTO All Models 90Y1177 WS 2008 SBS SP2 STD 64bit IT models CTO All Models 90Y1178 WS 2008 SBS SP2 STD 64bit JP models CTO All Models 90Y1179 WS 2008 SBS SP2 STD 64bit...

Страница 238: ...rive SATA models CTO 43W8466 5 Bezel Kit models CTO All Models 42C8942 6 Bezel upper models CTO 46U2947 7 Bezel lower models CTO 46U2948 8 Hard disk drive 250GB 7200 RPM 3 5 Simple Swap SATA II models CTO 11G 11M 11A 11J 45J9634 8 Hard disk drive 500GB 7200 RPM 3 5 Simple Swap SATA II models CTO 46U1024 8 Hard disk drive 250GB 7200 RPM 3 5 Hot Swap SATA II models CTO 45J9642 8 Hard disk drive 500G...

Страница 239: ...Models 69Y1013 14 ServeRAID BR10il SAS SATA controller models CTO 49Y4737 15 Microprocessor Celeron G1101 2 26GHz 1066MHz 2MB 2C models CTO 49Y4645 15 Microprocessor Xeon X3460 2 8GHz 1333MHz 8MB 4C models CTO 49Y4646 15 Microprocessor models CTO 49Y4647 15 Microprocessor Xeon X3440 2 53GHz 1333MHz 8MB 4C models CTO 49Y4648 15 Microprocessor Xeon X3450 2 67GHz 1333MHz 8MB 4C models CTO 49Y4649 15 ...

Страница 240: ...54 ServeRAID M1015 SAS SATA Controller models CTO 46M0862 ServeRAID MR10i Li Ion Battery models CTO 43W4301 ServeRAID MR10M SAS SATA Controller with Remote Battery Kit models CTO 43W4341 ServeRAID M1015 RAID 5 Upgrade Key models CTO 46M0864 ServeRAID M5014 SAS SATA Controller models CTO 46M0922 NetXtreme II 1000 Express Ethernet Adapter models CTO 39Y6070 PRO 1K PT Dual adapter models CTO 39Y6128 ...

Страница 241: ...tem service label models CTO All Models 49Y8452 USB hypervisor key models Virtual media key models 6529 Software FRU FRU EasyManage models CTO All Models 69Y9937 Documentation DVD models CTO All Models 90Y1164 EasyStartup models CTO All Models 90Y1165 WS2008 R2 FOUND 64bit US models CTO All Models 90Y1166 WS2008 R2 FOUND 64bit NL models CTO All Models 90Y1167 WS2008 R2 FOUND 64bit FR models CTO Al...

Страница 242: ...s 90Y1197 WS 2008 R2 ENT 64bit TR models CTO All Models 90Y1198 ROK WS2008 FOUND 64bit MUI EN JP models CTO All Models 90Y1199 ROK WS2008 FOUND 64bit MUI EN FR GR SP IT models CTO All Models 90Y1200 Table 22 Parts listing Type 6530 Index Description CRU part number Self service CRU part number Optional service FRU part number 1 Chassis assembly models CTO All Models 49Y8457 2 Operator Information ...

Страница 243: ...4J 45J9648 8 Hard disk drive IBM 450GB 15K SAS 3 5 HS HDD models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 12G 12M 12A 12J 13U 13F 13S 13L 13D 13Y 13G 13M 13A 13J 14G 14M 14A 14J 46U2108 8 Hard disk drive 73GB 15K 3 5 Hot Swap SAS HDD models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 12G 12M 12A 12J 13U 13F 13S 13L 13D 13Y 13G 13M 13A 13J 14G 14M 14A 14J 46U2088 8 Hard disk drive ThinkServer 30...

Страница 244: ... CTO All Models 49Y8447 18 Retention bracket rear adapter models CTO All Models 49Y8450 19 Power supply 401w PSU Fixed models CTO 46M6678 19 Power supply 430w PSU H S models CTO 11U 11F 11S 11L 11D 11Y 11G 11M 11A 11J 12G 12M 12A 12J 13U 13F 13S 13L 13D 13Y 13G 13M 13A 13J 14G 14M 14A 14J 46M6679 20 Memory 1GB DDR3 1333 1Rx8 LP RDIMM models CTO 46U1991 20 Memory 1GB 1x1GB Single Rankx8 PC3 10600 C...

Страница 245: ...49Y8461 Cable backplane configuration 3 5 inch hot swap hard disk drive models CTO All Models 49Y8448 Cable SAS signal 3 5 inch hot swap hard disk drive models CTO All Models 46M6498 Cable SATA signal 3 5 inch simple swap hard disk drive models CTO All Models 49Y8444 Cable 1Mx4 SAS Mini models CTO All Models 39R6530 Cable 3Mx4 SAS Mini models CTO All Models 39R6532 Cable optical disk drive tape dr...

Страница 246: ...els 90Y1172 WS2008 R2 FOUND 64bit TR models CTO All Models 90Y1173 WS 2008 SBS SP2 STD 64bit US models CTO All Models 90Y1174 WS 2008 SBS SP2 STD 64bit NL models CTO All Models 90Y1175 WS 2008 SBS SP2 STD 64bit FR models CTO All Models 90Y1176 WS 2008 SBS SP2 STD 64bit GR models CTO All Models 90Y1177 WS 2008 SBS SP2 STD 64bit IT models CTO All Models 90Y1178 WS 2008 SBS SP2 STD 64bit JP models CT...

Страница 247: ... Laboratories UL and certified by the Canadian Standards Association CSA For units intended to be operated at 115 volts Use a UL listed and CSA certified cord set consisting of a minimum 18 AWG Type SVT or SJT three conductor cord a maximum of 15 feet in length and a parallel blade grounding type attachment plug rated 15 amperes 125 volts For units intended to be operated at 230 volts U S use Use ...

Страница 248: ...zil 2 8M models CTO 39M5247 Taiwan 2 8M models CTO Table 24 Power cords Type 6523 Lenovo Power cord part number Used in these countries and regions 39M5068 Argentina 2 8M models CTO 11L 11Y 39M5081 US Canada 2 8M models CTO 11U 11F 11S 11L 11D 11A 39M5199 Japan 2 8M models CTO 11J 39M5123 Europe 2 8M models CTO 39M5165 Italy 2 8M models CTO 11S 11L 11Y 11G 39M5102 ANZ 2 8M models CTO 11M 39M5130 D...

Страница 249: ...ons 39M5068 Argentina 2 8M models CTO 11L 11Y 12L 12Y 14L 14Y 39M5081 US Canada 2 8M models CTO 11U 11F 11S 11L 11D 11A 12U 12F 12S 12L 12D 12A 13A 14U 14F 14S 14L 14D 39M5199 Japan 2 8M models CTO 11J 12J 13J 14J 39M5123 Europe 2 8M models CTO 39M5165 Italy 2 8M models CTO 11S 11L 11Y 11G 12S 12L 12Y 12G 13G 14S 14L 14Y 14G 39M5102 ANZ 2 8M models CTO 11M 12M 13M 14M 39M5130 Denmark 2 8M models C...

Страница 250: ...zil 2 8M models CTO 39M5247 Taiwan 2 8M models CTO Table 28 Power cords Type 6528 Lenovo Power cord part number Used in these countries and regions 39M5068 Argentina 2 8M models CTO 11L 11Y 39M5081 US Canada 2 8M models CTO 11U 11F 11S 11L 11D 11A 39M5199 Japan 2 8M models CTO 11J 39M5123 Europe 2 8M models CTO 39M5165 Italy 2 8M models CTO 11S 11L 11Y 11G 39M5102 ANZ 2 8M models CTO 11M 39M5130 D...

Страница 251: ...ountries and regions 39M5068 Argentina 2 8M models CTO 11L 11Y 13L 13Y 39M5081 US Canada 2 8M models CTO 11U 11F 11S 11L 11D 11A 12A 13U 13F 13S 13L 13D 13A 14A 39M5199 Japan 2 8M models CTO 11J 12J 13J 14J 39M5123 Europe 2 8M models CTO 39M5165 Italy 2 8M models CTO 11S 11L 11Y 11G 12G 13S 13L 13Y 13G 14G 39M5102 ANZ 2 8M models CTO 11M 12M 13M 14M 39M5130 Denmark 2 8M models CTO 11G 12G 13G 14G ...

Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...

Страница 253: ... presence and blue screen capture feature are integrated into the Integrated Management Module IMM The virtual media key is required to enable the remote presence functions When the optional virtual media key is installed in the server it activates the remote presence functions Without the virtual media key you will not be able to access the network remotely to mount or unmount drives or images on...

Страница 254: ...firmware some menu choices might differ slightly from these descriptions v System Information Select this choice to view information about the server When you make changes through other choices in the Setup Utility some of those changes are reflected in the system information you cannot change settings directly in the system information This choice is on the full Setup Utility menu only System Sum...

Страница 255: ...ings for the integrated management module POST Watchdog Timer Select this choice to view or enable the POST watchdog timer POST Watchdog Timer Value Select this choice to view or set the POST loader watchdog timer value Reboot System on NMI Enable or disable restarting the system whenever a nonmaskable interrupt NMI occurs Disabled is the default Commands on USB Interface Preference Select this ch...

Страница 256: ...stem event logs You can use the arrow keys to move between pages in the error log The system event logs contain all event and error messages that have been generated during POST by the systems management interface handler and by the system service processor Run the diagnostic programs to get more information about error codes that occur Important If the system error LED on the front of the server ...

Страница 257: ... user authority to set change and delete the power on password A user who types the power on password has access to only the limited Configuration Setup Utility menu the user can set change and delete the power on password if the system administrator has given the user that authority Power on password If a power on password is set when you turn on the server the system startup will not be complete...

Страница 258: ... Microprocessor Heatsink Orientation DIMMs DIMMs Table 31 System board jumpers Jumper number Jumper name Jumper setting JP1 Clear CMOS jumper 1 v Pins 1 and 2 Keep CMOS data default v Pins 2 and 3 Clear CMOS data including power on password and administrator password JP6 Boot block jumper 2 v Pins 1 and 2 Boot from primary BIOS page default v Pins 2 and 3 Boot from backup BIOS page Notes 1 If no j...

Страница 259: ...lled Table 32 RAID configuration utilities RAID configuration utility Description Location Where to find more information EasyStartup RAID configuration utility v For use with all factory supported RAID controllers v Automatically detects hardware and lists all supported RAID configurations v Configures one or more disk arrays per controller depending on the number of drives attached to the contro...

Страница 260: ...he LSI Configuration Utility program to configure and manage arrays consider the following information v The integrated SAS SATA controller with RAID capabilities supports the following features Integrated Mirroring IM with hot spare support also known as RAID 1 Use this option to create an integrated array of two disks plus up to two optional hot spares All data on the primary disk can be migrate...

Страница 261: ... to save back up the hard disk before you perform this procedure Note Before you format a hard disk make sure that the disk is not part of a mirrored pair To format a drive complete the following steps 1 From the list of adapters select the controller channel for the drive that you want to format and press Enter 2 Select SAS Topology and press Enter 3 Select Direct Attach Devices and press Enter 4...

Страница 262: ...er that is currently selected Scan Devices From this view you can re scan the physical and virtual disks for any changes in the drive status or physical configuration Virtual Disks From this view you can display and modify the virtual disk properties delete virtual disks initialize disks and perform other tasks Physical Drives From this view you can view the physical drive properties create hot sp...

Страница 263: ...ebBIOS screen Viewing and changing virtual disk properties On the WebBIOS main screen select a virtual disk from the list and click Virtual Disk The Properties panel displays the RAID level state size and stripe size The Policies panel lists the virtual disk policies that were defined when the storage configuration was created To change any of these policies select a policy from the menu and click...

Страница 264: ...ogram to install an operating system make sure any external storage devices and fiber channels are configured correctly EasyStartup overview The EasyStartup program requires a supported Lenovo server with an enabled startable bootable DVD drive In addition to the EasyStartup DVD you also must have the operating system installation CD or DVD and the product key or installation number for the operat...

Страница 265: ...ormation and legal notices Configuring RAID The RAID configuration feature that is part of the EasyStartup program enables you to view and change RAID settings for supported RAID controllers Through this feature you have the ability to configure each installed controller The program automatically detects the number of discs currently attached to the controller determines the possible RAID configur...

Страница 266: ... the EasyStartup program to install your operating system do the following to download the latest operating system installation instructions from the Lenovo Support Web site Note Changes are made periodically to the Lenovo Web site The actual procedure might vary slightly from what is described in this document 1 Go to http www lenovo com support 2 Enter your product number machine type and model ...

Страница 267: ...and adapter firmware and one time to update the HDD firmware 9 Select the firmware updates that you want to install Before distributing the firmware update to other servers ensure that your server can restart successfully without encountering hardware problems Starting the backup server firmware The system board contains a backup copy area for the server firmware This is a secondary copy of the se...

Страница 268: ...s Jumper number Jumper name Jumper setting JP1 Clear CMOS jumper 1 v Pins 1 and 2 Keep CMOS data default v Pins 2 and 3 Clear CMOS data including power on password and administrator password JP6 Boot block jumper 2 v Pins 1 and 2 Boot from primary BIOS page default v Pins 2 and 3 Boot from backup BIOS page Notes 1 If no jumper is present the server responds as if the pins are set to 1 and 2 2 Chan...

Страница 269: ... NMI by pressing an NMI button on the system board for an operating system memory dump ASR is supported by IPMI v Intelligent Platform Management Interface IPMI Specification V2 0 and Intelligent Platform Management Bus IPMB support v Invalid system configuration CNFG LED support v Serial port redirection over Telnet or SSH v Serial over LAN SOL v Query power supply input power v PECI 2 support v ...

Страница 270: ...fter the operating system has been installed Installation requirements Before installing ThinkServer EasyManage software on your server your environment must meet the following requirements v Microsoft Windows Server 2008 is installed on the server where you intend to install the Core Server v The original Windows Server operating system installation CDs are available in case files are needed whil...

Страница 271: ...ps in this section Installing Web Server Role IIS To install the Web Server Role IIS do the following 1 Click Start Server Manager 2 Under Roles Summary click Add Roles The Add Roles wizard appears 3 Click Next 4 Select the checkbox next to Web Server IIS A dialog box displays the additional features that are required 5 Click Add Required Features then click Next In the list of additional role ser...

Страница 272: ...des the following functions v Remotely viewing video with graphics resolutions up to 1280 x 1024 at 75 Hz regardless of the system state v Remotely accessing the server using the keyboard and mouse from a remote client v Mapping the DVD drive diskette drive and USB flash drive on a remote client and mapping ISO and diskette image files as virtual drives that are available for use by the server v U...

Страница 273: ...active for the number of minutes that you entered for the timeout value 4 Click Continue to start the session The System Health page provides a quick view of the system status Enabling the Intel Gigabit Ethernet Utility program The Intel Gigabit Ethernet Utility program is part of the server firmware You can use it to configure the network as a startable device and you can customize where the netw...

Страница 274: ...t b Update the UEFI code following the instructions that come with the update file that you downloaded 2 Update the IMM firmware a Download the latest version of the IMM firmware from http www lenovo com support b Update the IMM firmware following the instructions that come with the update file that you downloaded 3 Configure the UEFI settings a When you are prompted to start the Configuration Set...

Страница 275: ...ion Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo produc...

Страница 276: ...s vary and are often less than the possible maximum When referring to processor storage real and virtual storage or channel volume KB stands for 1024 bytes MB stands for 1 048 576 bytes and GB stands for 1 073 741 824 bytes When referring to hard disk drive capacity or communications volume MB stands for 1 000 000 bytes and GB stands for 1 000 000 000 bytes Total user accessible capacity can vary ...

Страница 277: ...ic equipment WEEE The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union This label is applied to various products to indicate that the product is not to be thrown away but rather reclaimed upon end of life per this Directive Remarque Cette marque s applique uniquement aux pays de l Union Européenne et à la Norvège L etiqu...

Страница 278: ...cal and Electronic Equipment EEE Türkiye EEE Yönetmeliğine Uygunluk Beyanı T C Çevre ve Orman Bakanlığı nın Elektrik ve Elektronik Eşyalarda Bazı Zararlı Maddelerin Kullanımının Sınırlandırılmasına Dair Yönetmelik EEE direktiflerine uygundur EEE Yönetmeliğ Bu Lenovo ürünü ine Uygundur Recycling statements for Japan 270 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Ma...

Страница 279: ...med upon end of life per this Directive Les batteries ou emballages pour batteries sont étiquetés conformément aux directives européennes 2006 66 EC norme relative aux batteries et accumulateurs en usage et aux batteries et accumulateurs usés Les directives déterminent la marche à suivre en vigueue dans l Union Européenne pour le retour et le recyclage des batteries et accumulateurs usés Cette éti...

Страница 280: ...requency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to me...

Страница 281: ...gen der EU Richtlinie 2004 108 EG früher 89 336 EWG zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU Mitgliedsstaaten und hält die Grenzwerte der EN 55022 Klasse A ein Um dieses sicherzustellen sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben Des Weiteren dürfen auch nur von der Lenovo empfohlene Kabel angeschlossen wer...

Страница 282: ...ost und Telekommunikation oder des Bundesamtes für Post und Telekommunikation betrieben werden Die Genehmigung wird erteilt wenn keine elektromagnetischen Störungen zu erwarten sind Auszug aus dem EMVG Paragraph 3 Abs 4 Dieses Genehmigungsverfahren ist nach Paragraph 9 EMVG in Verbindung mit der entsprechenden Kostenverordnung Amtsblatt 14 93 kostenpflichtig Anmerkung Um die Einhaltung des EMVG si...

Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...

Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...

Страница 285: ...stalling 193 removing 130 cover side installing 131 CPU 1 error LED 122 CPU 2 error LED 122 CPU mismatch LED 122 creating RAID array 253 CRUs installing battery 189 CRUs removing battery 188 customer replaceable units CRUs 202 D data collection 14 dc power LED 116 deassertion event system event log 19 device hypervisor flash installing 161 diagnosing a problem 14 diagnostic error codes 68 LEDs err...

Страница 286: ...61 I IBM Advanced Settings Utility program overview 262 IDs for SAS hot swap drives 147 IMM error messages 29 heartbeat LED 123 overview 9 IMM heartbeat LED 64 IMM IP address obtaining 264 in band method of recovering the server firmware 106 indicators 113 installing adapters 154 an adapter 156 battery 189 bezel lower 133 upper 134 CD drive 142 cover 193 diskette drive 142 drives bay 1 2 or 3 142 ...

Страница 287: ...ower control button power on LED 114 power cord connector 116 power error LED 116 power on LED 124 power on password 248 power on self test POST 18 Preboot diagnostics program 9 problem isolation tables 49 problem diagnosing 14 problems CD ROM DVD ROM drive 50 Ethernet controller 109 hard disk drive 51 IMM 29 intermittent 52 keyboard 52 memory 54 microprocessor 55 monitor 55 mouse 53 optional devi...

Страница 288: ...t 19 system information LED 115 system locator LED 115 systems management 9 T tape drive installing 142 145 remove 144 temperature 12 test log viewing 68 thermal grease 185 three boot failure 107 TOE 11 tools diagnostic 17 trademarks 268 troubleshooting procedures 16 start here 13 turning off the server 125 integrated baseboard management controller 125 TÜV gloss statement 272 two piece bezel 190 ...

Страница 289: ......