381298/C
209
7
Release a COM port.
a
On the left side of the
Installation
dialog box, click
I/O Setup
.
Observe that the
I/O Setup
page is shown.
b
Observe the list of serial ports.
c
If you have a vacant COM port, select it, then click
Remove
to delete it from
the list.
d
Click
Apply
in the bottom of the
Installation
dialog box, then OK to close it.
e
Restart the SN90 program to free the port.
f
When the SN90 program has started, return to the
Motion Reference Unit
page
to put the COM port to use.
Further requirements
If you choose a serial COM port to interface the motion sensor, make sure that you do
not put the same COM port to other use in the
I/O Setup
dialog box.
Related topics
Moxa CP114EL-I Serial line adapter, page 155
RS-232 serial line connection using three wires, page 163
RS-232 serial line connection using five wires, page 164
RS-422 serial line connection using five wires, page 165
Moxa CP114EL-I Serial line adapter, page 167
IP addressing and UDP port principles, page 212
Setting up the SN90 in a synchronized system
If you wish to use the SN90 as a master or slave in a synchronized system, you must set
it up for such operation. To do this, you must select which communication port to use for
the synchronization interface, and you must select the requested synchronization mode.
Prerequisites
For "slave" operation, a remote system (for example
K-Sync
) must be available to
provide trigger pulses. For "master" operation, a remote system must be connected. This
remote system must be set up in "slave" mode.
Context
Whenever more than one hydroacoustic system is installed on a vessel, interference may
occur. To avoid this, the systems may either be connected to a common synchronization
system, or one of the acoustic systems may be defined as a "master", and control the
transmission on the other system(s).
The SN90 includes interface for remote transmit synchronisation. It can be set up to
operate in either
Master
or
Slave
mode in relation to an external synchronization or
an other hydroacoustic system.
Содержание Simrad SN90
Страница 2: ......
Страница 117: ...381298 C 115 Related topics Installation summary page 65 Installing the transducer ...
Страница 226: ...224 381298 C 427 385 All measurements in mm The drawing is not in scale 385609 Rev B CD12_385609_001_002 Simrad SN90 ...
Страница 236: ...234 381298 C 372915 Clamping frame Simrad SN90 ...
Страница 295: ......
Страница 296: ... 2016Kongsberg Maritime ISBN 978 82 8066 179 1 ...
Страница 297: ......