196
381298/C
Procedure
1
Click the
Setup
icon.
The icon is located under the
Main
menu. It is used to open the
Setup
menu.
2
On the
Setup
menu, click
Installation
.
Observe that the
Installation
dialog box opens. This dialog box contains a number
of pages selected by the menu on the left side.
3
On the left side of the
Installation
dialog box, click the small white triangle next to
Installation Parameters
.
Observe that a menu opens with access to all the individual sub-pages.
4
On the left side of the
Installation
dialog box, click
Sonar Reference Point
to open
the page.
5
From the vessel drawings, extract the ship dimensions - length and width - and
insert those values.
Do this as accurately as possible.
6
If you wish to keep the default reference point, leave all offset values to 0 (zero).
7
If you wish to move the reference point to another location, use the necessary
offset values.
To find these offset values, consult the vessel drawings. Define the values as
accurately as possible.
8
At the bottom of the dialog box, click
Apply
to save your settings.
Result
A common reference point for the SN90 sensors and transducer is now established.
Further requirements
You must proceed by defining the locations of the navigation system antenna, the motion
reference sensor, and the transducer. These locations are all referenced to the sonar
reference point.
Related topics
Transducer installation principles, page 67
Determining the location and installation angles of the transducer, page 88
Vessel coordinate system, page 61
Installation remarks, page 216
Simrad SN90
Содержание Simrad SN90
Страница 2: ......
Страница 117: ...381298 C 115 Related topics Installation summary page 65 Installing the transducer ...
Страница 226: ...224 381298 C 427 385 All measurements in mm The drawing is not in scale 385609 Rev B CD12_385609_001_002 Simrad SN90 ...
Страница 236: ...234 381298 C 372915 Clamping frame Simrad SN90 ...
Страница 295: ......
Страница 296: ... 2016Kongsberg Maritime ISBN 978 82 8066 179 1 ...
Страница 297: ......