84
381298/C
Note
Observe relevant requirements and guidelines from the classification society, and make
sure that the conduit is properly supported, strong and watertight.
Finalize the steel conduit installation before you pull the transducer cable through it.
Make sure that there are no spatter, sharp edges or protruding objects that can damage
the transducer cables. If a cable is damaged, and penetrated by water, the transducer
will be damaged beyond repair.
Once the transducer is installed, the transducer cables – with the large transceiver plug
– must be pulled through the steel conduit. If you must introduce bends on the steel
conduit, take the size of the transceiver plug and the minimum cable bending radius into
consideration. Once you have pulled the cable up through the steel conduit, seal the top
of the conduit with a Roxtec (or similar) seal.
Steel conduit minimum dimensions
The dimensions of the steel conduit must be specified and/or verified by the relevant
maritime authority and/or classification society. The minimum dimensions are:
•
Inside diameters
:
– With transceiver plug mounted: 182 mm
– Without transceiver plug: 110 mm
•
Steel conduit wall thickness
: 7 mm
•
Steel type
: Match the steel type used for existing decks and bulkheads
Related topics
Three suggested methods, page 82
Simrad SN90
Содержание Simrad SN90
Страница 2: ......
Страница 117: ...381298 C 115 Related topics Installation summary page 65 Installing the transducer ...
Страница 226: ...224 381298 C 427 385 All measurements in mm The drawing is not in scale 385609 Rev B CD12_385609_001_002 Simrad SN90 ...
Страница 236: ...234 381298 C 372915 Clamping frame Simrad SN90 ...
Страница 295: ......
Страница 296: ... 2016Kongsberg Maritime ISBN 978 82 8066 179 1 ...
Страница 297: ......