381298/C
105
• Fish tape (wire pulling tool) with suitable length
Context
When you use an SN90 or SN91 transducer with the large transceiver plug mounted, all
necessary precautions must be made to avoid damage to the cables and the plug while
pulling the cables through the steel conduit.
Note
Make sure that all welding has been finalized before you pull the cables through the steel
conduit. Heat may cause serious damage to the cables and the transducer.
Procedure
1
Verify that the steel conduit has been finished, and that all welding has been
finalized.
2
Lower the fish tape (wire pulling tool) down from the top of the steel conduit,
and through the sealing plate.
3
Fasten the end of the fish tape to the transducer cables using electrician’s tape.
4
Pull the cables carefully up through the steel conduit.
Continue until you reach the Transceiver Unit. Leave some slack close to the
Transceiver Unit, and immediately over the transducer.
Note
Be careful! Make sure that you do not damage neither the outer surface of the
transducer cables nor the large Transceiver Unit connector. If water leaks into a
cable, it may damage the transducer beyond repair.
5
Seal the top of the steel conduit with a Roxtec (or similar) multi-diameter cable
sealing.
Related topics
Installation summary, page 65
Using multi-diameter cable sealing, page 108
Содержание Simrad SN90
Страница 2: ......
Страница 117: ...381298 C 115 Related topics Installation summary page 65 Installing the transducer ...
Страница 226: ...224 381298 C 427 385 All measurements in mm The drawing is not in scale 385609 Rev B CD12_385609_001_002 Simrad SN90 ...
Страница 236: ...234 381298 C 372915 Clamping frame Simrad SN90 ...
Страница 295: ......
Страница 296: ... 2016Kongsberg Maritime ISBN 978 82 8066 179 1 ...
Страница 297: ......