Minimum cable requirements
•
Conductors
: 2 x 1.5 mm² + Ground
•
Screen
: None
•
Voltage
: 750 V
•
Maximum outer diameter
: Defined by the plugs and/or the cable gland
Related topics
Connecting the Uninterruptible Power Supply (UPS) to AC mains and vessel ground,
page 138
Connecting AC mains and ground to the Processor Unit, page 139
Connecting power and ground to the Transceiver Unit, page 140
Connecting AC mains and ground to the display, page 141
Connecting the Operating Panel Power Supply to the Processor Unit, page 142
Connecting ground to the Operating Panel, page 147
Grounding cable
Correct grounding is essential for safe operation and maximum performance.
GROUND
TAG
(CD0803_100_001)
A
Ground tag on unit cabinet
B
Vessel ground
The ground cable is a single conductor 6 mm² cable.
It is normally provided with a green/yellow colour. This
cable must be provided by the installation shipyard.
Minimum cable requirements
•
Conductors
: 1 x 6 mm²
•
Screen
: None
•
Voltage
: 60 V
•
Maximum outer diameter
: N/A
Related topics
Connecting the Uninterruptible Power Supply (UPS) to AC mains and vessel ground,
page 138
Connecting AC mains and ground to the Processor Unit, page 139
Connecting power and ground to the Transceiver Unit, page 140
Connecting AC mains and ground to the display, page 141
Connecting the Operating Panel Power Supply to the Processor Unit, page 142
Connecting ground to the Operating Panel, page 147
Содержание Simrad SN90
Страница 2: ......
Страница 117: ...381298 C 115 Related topics Installation summary page 65 Installing the transducer ...
Страница 226: ...224 381298 C 427 385 All measurements in mm The drawing is not in scale 385609 Rev B CD12_385609_001_002 Simrad SN90 ...
Страница 236: ...234 381298 C 372915 Clamping frame Simrad SN90 ...
Страница 295: ......
Страница 296: ... 2016Kongsberg Maritime ISBN 978 82 8066 179 1 ...
Страница 297: ......