381298/C
107
Context
(CD010205_100_001)
A
Transducer body
B
Clamping frame
C
Mounting bolts
D
Mounting house
E
Transducer cables
The transducer is installed
into the mounting house, and
secured with the clamping
frame. Observe the location
of the orientation bolt, as well
as the notch in the mounting
house. This side of the
mounting house shall always
point up!
Procedure
1
Lift the transducer into the
mounting house.
Observe the guide pin! The transducer will only fit in one direction.
2
While holding the transducer inside the mounting house, place the clamping frame
into position.
3
Apply Loctite 270, and fasten the clamping frame with the mounting bolts provided.
Important
Use maximum torque 35 Nm.