RS-232 serial line connection using five wires
An RS-232 serial line connection using five (5) wires and NMEA telegrams is a common
way to connect the SN90 to external devices.
(CD0801_002_001)
7
2
3
5
8
Rx
Rx
Tx
Tx
GROUND
GROUND
RTS
RTS
CTS
CTS
7
2
3
5
6
9
6
1
5
5
1
6
9
(CD0801_001_002)
A
Local connection
B
Connection on peripheral device
C
Female 9–pin D-connector
D
Male 9–pin D-connector
Unless otherwise specified, the serial line cable must be
provided by the installation shipyard.
Note that this cable does not support all the signals in the
standard RS-232 specification.
Minimum cable requirements
•
Conductors
: 2 x 4 x 0.5 mm²
•
Screen
: Overall braided
•
Voltage
: 60 V
•
Maximum outer diameter
: Defined by the plugs
If you need to install a very long serial line cable, increase the cross section.
Related topics
Connecting external devices to the Processor Unit using serial interfaces, page 148
IP addressing and UDP port principles, page 212
Setting up the input from a navigation system, page 204
Setting up the input from a Motion Reference Unit (MRU), page 208
Simrad SN90
Содержание Simrad SN90
Страница 2: ......
Страница 117: ...381298 C 115 Related topics Installation summary page 65 Installing the transducer ...
Страница 226: ...224 381298 C 427 385 All measurements in mm The drawing is not in scale 385609 Rev B CD12_385609_001_002 Simrad SN90 ...
Страница 236: ...234 381298 C 372915 Clamping frame Simrad SN90 ...
Страница 295: ......
Страница 296: ... 2016Kongsberg Maritime ISBN 978 82 8066 179 1 ...
Страница 297: ......