3-12
KLP070312
5. Press
DC OUTPUT
to accept the displayed settings. The unit briefly flashes
WAIT
, then
restarts with the new settings; press
FUNCTION
to abort without changing the settings.
NOTE: Until both units are configured properly, the displays will cycle as follows: status display
will flash
E241
(hardware error), then
DC VOLTS,
status display
and
DC AMPERES
flash
x
OF
y
where
x
= unit number and
y
= total number of units, the status display
flashes the type of connection
SERI
(series) or
PARA
(parallel).
3.2.13.3 OPERATING THE MASTER/SLAVE CONFIGURATION [STANDARD MODELS ONLY]
Once the master is configured, it searches for the slave specified. Until the slave is set up prop-
erly, the master status display will cycle as follows: status display will flash
E241
(hardware
error), then
DC VOLTS,
status display
and
DC AMPERES
flash
x
OF
y
where
x
= unit number
and
y
= total number of units, the status display flashes the type of connection
SERI
(series) or
PARA
(parallel). When the slave is found, the status display of the slave reads
SLVE
and the
DC
VOLTS
and
DC AMPERES
displays on the slave go blank. For the master/slave combination to
work properly the number of slave units specified in the master (PAR. 3.2.13.2, step 4) must be
found.
When the slave has been found, the master proceeds with the normal turn-on sequence and the
unit proceeds to
SET
mode. The master front panel readouts show the total values for set point,
voltage and current readback, virtual model (the virtual model and protection settings of the
slave are automatically programmed to be the same as the master) and protection settings for
the master/slave configuration. All controls on the slave are disabled. The parallel or series
combination is controlled from the master using either the front panel, SCPI commands, or ana-
log control.
• If analog control is used, only the master is configured for analog control (the slave is
controlled digitally by the master).
• If Remote Inhibit is used, it should only be connected to the master.
• If
E241
(hardware error) is showing in the status display, check the master and/or slave
setup. If necessary, use
FUNCTION
switch to enter the M/S menu to change the config-
uration as described above.
• If there is no communication between units for approximately 10 seconds, all units will
turn off their output and the status display will flash
E241
(hardware error), then
xOFy
where
x
= unit number and
y
= total number of units, and finally the serial/parallel config-
uration setting
SERI
or
PARA
.
• Fault recovery mode (PAR. 3.2.16.3.2) for all faults is fixed as PROTected mode.
• Calibration cannot be performed on a master/slave pair; the individual units must be
reconfigured back to independent mode (PAR 3.2.13.4) and then calibrated as individual
units.
• Baud rate is automatically adjusted to highest supportable rate as part of master/slave
setup and cannot be adjusted by user.
• LIST, VOLT:MODE TRANS and CURR:MODE TRANS commands are not supported for
master/slave pairs.
Содержание KLP 10-150-2
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP070312 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 19: ...KLP 070312 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Страница 20: ...1 8 KLP 070312 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 27: ...KLP HV 070312 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......
Страница 78: ......
Страница 90: ......