3-2
KLP070312
• Status display flashes
PROT
for 2 seconds while
DC VOLTS
and
DC AMPERES
dis-
plays show previously stored OVP and OCP trigger levels. NOTE: to reprogram OVP
or OCP, refer to PAR. 3.2.10.
NOTE: To eliminate the display of model, virtual model, and protection levels on power-up,
refer to PAR. 3.2.16.2 for quick boot.
• For E-Series models, the LAN indicator blinks rapidly during initialization. If an IP
address is found, it stays on without blinking. If an IP address is not found, the LAN
indicator stays off.
• If any fault is configured for AUTO recovery (see PAR. 3.2.16.3.2), the status display
flashes
AUTO
for one second.
• If remote inhibit is active (see PAR. 3.4.1) upon power-up, the status display flashes
rINH
for one second.
• If an error occurs, an error code is displayed in the status display (see Table 3-1).
3. After a successful self test, the default conditions upon power up are as follows:
• Status display shows
SET
.
• output is disabled (green
DC OUTPUT
indicator is off). If remote analog mode is
selected (PAR. 3.4), output is enabled unless Remote Inhibit, pin 8 of the Analog I/O
Connector (see Figure 2-2 and Table 2-7) is grounded.
•
DC VOLTS
and
DC AMPERES
displays show programmed output conditions: either 0
Volts, minimum Amperes (see NOTE, PAR. 3.2.1) or, if DIP switch position 3 enabled
(see Table 2-2), previously saved setpoint values in effect upon power off.
TABLE 3-1. POWER-UP BUILT-IN TEST ERROR CODES
ERROR CODE
MEANING
E310
System Error
E313
Calibration Memory Error
E315
Configuration Memory Error
E341
Memory Error (CRC)
E330
Self Test Error
Ecal
Calibration Error - The unit will try to restore the previous calibration.
Eclp
Previous Calibration Error - After detecting a Calibration Error (Ecal) and trying to use
the previous calibration, an error was detected, and the unit will attempt to restore the
factory calibration.
Eclf
Factory Calibration Error - The unit has failed to restore the factory calibration after
failing to restore the previous calibration. The unit will not operate after this error has
been displayed and must be referred for service.
NOTE: During power-up the power supply performs detailed software check sequences. If a failure is detected dur-
ing power-up, the DC VOLTS and DC AMPERES displays are blanked and the Status display shows an error code.
For errors that occur after power-up, refer to the Developer’s Guide for typical error codes and possible causes. For
these and all other error codes, refer to authorized service personnel if corrective action is required.
Содержание KLP 10-150-2
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP070312 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 19: ...KLP 070312 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Страница 20: ...1 8 KLP 070312 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 27: ...KLP HV 070312 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......
Страница 78: ......
Страница 90: ......